The operation state of the Alarm relay can be set to continuous or intermittent operation. In intermittent operation the relay
switches on and off every 0.8 seconds.
DVCC settings
The discharge current limit at pre-alarm setting is set by default set to "no". This can be changed to "yes".
The absorption time is set by default to 2hours. This can be adjusted if required.
The state of charge (SoC) threshold is set by default to 70%. This is the threshold at which the Lynx Smart BMS starts a new
full charging cycle. This can be adjusted if required.
The repeated absorption time in days at which a new full charging cycle is started if the battery state of charge does not fall
below the SoC threshold. The default is every 30 days and can be adjusted if required.
Battery Monitor settings
The charged voltage is the voltage at above which the battery monitor synchronises and resets the state of charge to 100%.
For synchronisation to happen, the tail current and charged detection time conditions need to have been met as well. The
default is set to 14.0V and can be adjusted if required.
The tail current is the current at below which the battery monitor synchronises and resets the state of charge to 100%. For
synchronisation to happen, the charged voltage and charge detection time conditions need to have been met as well. The
default is set to 4.00% and can be adjusted if required.
The charged detection time is the time passed after which the battery monitor synchronises and resets the state of charge to
100%. For synchronisation to happen, the charged voltage and charged current conditions need to have been met as well. The
default is set to 3 minutes and can be adjusted if required.
VictronConnect setting Lynx Smart BMS
6.3.4. Settings Lynx Distributor
These instructions only apply if the system contains a Lynx Smart BMS.
Use the VictronConnect App to give each fuse a custom name (maximum 16 characters). If the fuse name is empty (0
characters), the fuse will be disabled from monitoring and be ignored.
Navigate to the settings page by clicking the gear symbol at the top right-hand corner.
On the settings page scroll down to the Lynx Distributor settings.
Click on a fuse name and a window opens to rename the fuse.
Lynx Smart BMS
Page 18 Installation
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Lynx Smart BMS 500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Lynx Smart BMS 500 in the language / languages: English as an attachment in your email.

The manual is 3.23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info