785222
20
Zoom out
Zoom in
Previous page
1/40
Next page
RJ45 VE.Can
connectors
Location VE.Can connectors Lynx Smart BMS
6.3. Make settings
6.3.1. Power up for the first time
The Lynx Smart BMS will power up when a battery is connected to the battery terminals and the remote on/off switch is turned on
(or the wire loop is placed in the remote on/off connections). This will be the case once the battery pole has been connected. Or
the battery fuses have been placed.
On first power up (or after a reset to factory defaults) the Lynx Smart BMS will automatically determine the system voltage by
measuring the battery voltage and stores this in its memory. In order to determine the correct system voltage, it is essential that
the battery is charged up to at least its nominal voltage (12.8V or 25.6V) to avoid false detection.
On first power up (or after a reset to factory defaults) the Lynx Smart BMS will also automatically detect if the connected battery is
equipped with the pre-alarm hardware and stores this in its memory (Older batteries might not have pre-alarm hardware). It is
essential that the battery BMS cables are connected to the Lynx Smart BMS before power up.
6.3.2. Update firmware
On first connection, VictronConnect can ask you to update the firmware of the Bluetooth interface and/or of the Lynx Smart BMS
This should always be done on first install. Without up to date firmware settings cannot be changed and only monitoring is active.
6.3.3. Settings Lynx Smart BMS
Once powered up the VictronConnect app is used to make essential and custom settings.
Check and update firmware:
Check if the firmware of the Lynx Smart BMS is up to date and update if a newer version is available.
Check if the firmware of each battery is up to date and update if a newer version is available.
Set battery voltage:
This would have been detected automatically, but check it anyway, just to make sure.
Set battery capacity
Enter the battery capacity of the connected battery bank.
Set pre-alarm:
Check if the pre-alarm is enabled. This would have been detected automatically, but check it anyway, just to make sure. Note
that this setting is only available if the connected batteries have the necessary pre-alarm hardware. (older batteries might not
have the pre-alarm feature).
The pre-alarm voltage setting is set in the battery (not in the Lynx Smart BMS). If multiple batteries are used, the pre-alarm
voltage setting needs to be set at the same value in each battery.
Alarm relay:
Lynx Smart BMS
Page 17 Installation
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Lynx Smart BMS 500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Lynx Smart BMS 500 in the language / languages: English as an attachment in your email.

The manual is 3.23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info