16
an extremely high charging current with
respect to battery capacity, so that bulk
time is insufficient.
The battery is overcharged.
The absorption voltage is set to an
incorrect level (too high).
Set the absorption voltage to the correct
level.
The float voltage is set to an incorrect
level (too high).
Set the float voltage to the correct level.
Poor battery condition.
Replace the battery.
The battery temperature is too high (due
to poor ventilation, excessively high
environmental temperature, or
excessively high charging current).
Improve ventilation, install batteries in a
cooler environment, reduce the charging
current,
and connect the temperature
sensor.
The charging current drops to 0 as soon
as the absorption phase initiates. Defective battery temperature sensor
Disconnect the temperature sensor plug
in the EasySolar-II GX. If charging
functions correctly after approximately 1
minute, the temperature sensor should
be replaced.
The battery is over-heated (+50°C)
Install the battery in a cooler
environment
Reduce the charging current
Check whether one of the battery cells
has an internal short circuit
11.2 VE.Bus error codes
A VE.Bus system can display various error codes. These codes are displayed on the front GX display screen.
To interpret a VE.Bus error code correctly, you should refer to the VE.Bus error codes documentation -
https://www.victronenergy.com/live/ve.bus:ve.bus_error_codes.
Code
Meaning:
Cause/solution:
1
Device is switched off because one of the other
phases in the system has switched off.
Check the failing phase.
3 Not all, or more than, the expected devices were
found in the system.
The system is not properly configured. Reconfigure the
system. If the error persists, possible communication cable
error. Check the cables and switch all equipment off, and then
on again.
4
No other device whatsoever detected.
Check the communication cables.
5
Overvoltage on AC-out.
Check the AC cables.
10 System time synchronisation problem occurred.
Should not occur in correctly installed equipment. Check the
communication cables.
14 Device cannot transmit data.
Check the communication cables (there may be a short
circuit).
17
One of the devices has assumed 'master' status
because the original master failed.
Check the failing unit. Check the communication cables.
18
Overvoltage has occurred.
Check AC cables.
22 This device cannot function as 'slave'.
This device is an obsolete and unsuitable model. It should be
replaced.
24 Switch-over system protection initiated.
Should not occur in correctly installed equipment. Switch all
equipment off, and then on again. If the problem recurs,
check the installation.
Possible solution: increase lower limit
of AC input voltage to 210 VAC (factory setting is 180 VAC)
25
Firmware incompatibility. The firmware of one the
connected devices is not sufficiently up to date to
operate in conjunction with this device.
1) Switch all equipment off. 2) Switch the device returning
this error message on. 3) Switch on all other devices one by
one until the error message reoccurs. 4) Update the firmware
in the last device that was switched on.
26 Internal error.
Should not occur. Switch all equipment off, and then on
again. Contact Victron Energy if the problem persists.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron EasySolar-II 48 3000 35-32 MPPT 250 70 GX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron EasySolar-II 48 3000 35-32 MPPT 250 70 GX in the language / languages: English, German, Dutch, French, Italian, Swedish, Spanish as an attachment in your email.

The manual is 2.84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info