6. Configuring the Digital Multi Control panel
This chapter describes the configuration parameters and procedure.
6.1 Procedure
During configuration 6 parameters can be set. The configuration procedure is straight forward.
- To enter the configuration mode press the button on the back of the DMC until the bottom
LED in the left column starts flashing, indicating that the first parameter can be changed.
- To change the value of a parameter, turn the knob until the displayed value is as required.
- Press the button to advance to the next parameter.
The lower three LEDs in the left column on the DMC indicate which parameter is being
adjusted according to the table below:
LED
indication Selected parameter
Scaling factor. default:0, range:0-9
(this parameter is ignored when using
VE.Bus devices)
Generator current limit in Amps.
default:16, range:0..198
Upper shore limit for AC input 1 in Amps.
default:254, range:0..254
Upper shore limit for AC input 2 in Amps.
default:254, range:0..254
Upper shore limit for AC input 3 in Amps.
default:254, range:0..254
Upper shore limit for AC input 4 in Amps.
default:254, range:0..254
means LED is off, means LED is blinking, means LED is on
Notes:
- The connected Multis or Quattro’s switch to “Inverter only” when the configuration button is
pressed and during configuration mode.
- Pressing the button when the last parameter of the table is selected will end configuration mode
and activate all parameters. So even if only one parameter needs to be adjusted you have step
through all parameters to exit the configuration mode.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Digital Multi Control 200A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Digital Multi Control 200A in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 0.41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info