5. Using the Digital Multi Control panel
The DMC is used to remotely set up to four (five including the generator functionality) different
input currents, read out the status of your system and turn on and off the Multis or Quattro’s.
5.1 Turning the system on and off
Use the switch on the front to turn the system on, off or to charger only operation.
5.2 Setting the system input current limit
The shore current limit is set by the control knob on the DMC. Turn the knob right or left to set the
desired value. The current limit will be shown on the 7-segment display.
The generator current limit can be set during installation. See chapter 6 for detailed instructions.
When PowerAssist is enabled there is a minimum AC input current limit of approximately 2-3Amp
per device. Setting a lower limit than this minimum will result in the minimum limit. This is normal
Multi/Quattro behavior.
There is a feature in the Multi/Quattro that, when PowerAssist is enabled and the shore current
setting from the remote panel is zero amps, the internal transfer relay is opened and the device
starts inverting.
VE.Bus only:
- The DMC will not allow you to set a limit lower than the minimum shore current limit.
To be able to use the above mentioned feature, the DMC allows the operator to set the shore
current limit to 0 Amps which is actually below the minimum shore current limit. To achieve this,
the operator must turn the knob ‘downwards’ with a higher speed. The display will then ‘jump’ to
0.0 and the connected device(s) will start inverting. When the knob is turned upwards again the
display will ‘jump’ to the minimum shore current limit.
- If your system has more than 1 AC input the display will also indicate which input is currently in
use by displaying , , or .
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Digital Multi Control 200A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Digital Multi Control 200A in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 0.41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info