3838 3-90-30007498Vermont Castings • Radiance RADVT Installation Manual_R32 • 10/23
M.Troubleshooting-(Continued)
Symptom PossibleCause Corrective Action
Pilot sparks but does not light, after 90
sec, 3 Red/1 Green Lockout
No gas supply.
Verify incoming gas line ball valve is ‘Open’. Verify inlet
pressure is within requirement for gas type used. Contact
gas supplier.
ECM has poor ground. Verify wiring, check valve harness black wire is securely
grounded to metal chassis.
Gas valve defective.
Check pilot valve solenoid kick and hold voltages during
ignition cycle. Kick V should be >1 V, hold V minimum
0.26 V. If voltages are OK, replace gas valve.
Pilot lights but main burner does not
light. Pilot continues to spark for 90 sec
then goes into 3 Red/1 Green Lockout.
No ame detected. Flame
rectication issue.
Check if white sense lead is securely connected to
‘S’ terminal of IFT-ECM. Check resistance of sense
lead between sense rod tip and connector to IFT-ECM,
should be less than 1 ohm - if not, replace pilot assembly.
Check system ground, ensure black valve harness wire
is securely attached to metal chassis. Check wiring for
damage. With system OFF, check resistance between
tip of sense rod and pilot hood, should be resistance (>1
M-ohm).
No ame detected or sense
rod contamination.
With glass assembly installed, verify pilot ame is
engulng ame sense rod on pilot assembly. Verify inlet
gas pressure is correct for gas type. Polish ame sense
rod with ne steel wool to remove any contaminants that
may have accumulated.
Pilot lights and recties, but main burner
does not light. Main valve solenoid.
Check if green wire in valve harness is connected to
green main valve solenoid. Check main valve solenoid
resistance, nominal is 60 ohms. If open or shorted, replace
valve. Verify valve inlet pressure is correct for gas type.
Pilot and main do not light, ECM goes
into 5 Red/1 Green Lockout. Power Vent (PV) Failure.
Power Vent blower defective - check wiring to IFT-ACM,
check if blower is working. Check if PV pressure switch
is connected to brown and black wire in 6-pin valve wire
harness. Check if pressure switch is closed (shorted)
when PV blower is running. Refer to PV troubleshooting
instructions.
Appliance lights and runs for a few
minutes then shuts down and/or
appliance cycle ON and OFF with less
than 90 sec of ON time.
Shorted or loose connection
in ame detection circuit.
Check if white sense lead is securely connected to
‘S’ terminal of IFT-ECM. Check resistance of sense
lead between sense rod tip and connector to IFT-ECM,
should be less than 1 ohm - if not, replace pilot assembly.
Check system ground, ensure black valve harness wire
is securely attached to metal chassis. Check wiring for
damage. With system OFF, check resistance between
tip of sense rod and pilot hood, should be resistance (>1
M-ohm).
Poor ame rectication or
contaminated sense rod.
With glass assembly installed, verify pilot ame is
engulng ame sense rod on pilot assembly. Verify inlet
gas pressure is correct for gas type. Polish ame sense
rod with ne steel wool to remove any contaminants that
may have accumulated. Verify no soot deposits are in
sense rod to pilot hood gap.
Logs are set up wrong. Remove and re-install logs per the log placement
instructions.
Damaged pilot assembly.
Verify the pilot assembly ceramic insulator around the
ame sensing rod is not cracked, damaged or loose.
Check resistance between tip of sense rod and IFT-ECM
connector, should be less than 1 ohm. Replace pilot
assembly if damage is detected.
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vermont Castings Radiance Series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vermont Castings Radiance Series in the language / languages: English as an attachment in your email.

The manual is 6.69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vermont Castings Radiance Series

Vermont Castings Radiance Series User Manual - French - 46 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info