L.FrequentlyAskedQuestions-IntelliFire™TouchControls(IFT-RC400)
Symptom PossibleCause Corrective Action
The appliance does not respond to
commands from the remote control
display does not light up when
screen is touched.
Batteries are depleted. Verify batteries are new.
Batteries are incorrectly
oriented.
Verify batteries are installed in correct orientation as shown on
batteries receptacle.
The display on remote lights up
when screen is touched but it does
not respond to commands.
Touchscreen has lost
calibration.
Touchscreen needs to be re-calibrated. Call dealer to have
screen re-calibrated.
Child Lock is ON.
Check child lock icon located at the top of the remote display. If
ON, it will show as a ‘locked’ symbol. To unlock, remove battery
compartment door, locate child lock switch and move to ‘unlock’
position. Verify child lock icon on screen is now displayed in
‘unlock’ position.
The remote displays the following
message on-screen:
No dealer info available
Dealer information not
programmed into remote.
Remote will still provide all available functions, and appliance is
fully available for use. Call dealer to have them program.
The remote displays the following
message on-screen:
Call “Dealer Name & Number” to
schedule maintenance.
300 hours of use. Appliance is
still fully functional.
The appliance has been burning for 300 hours and is due
for a regular maintenance. Call dealer to have them perform
maintenance.
The room temperature displayed
on the remote is either slow or
quick to respond while operating in
thermostat mode.
Remote is placed at a very
short distance or too far away
from the appliance.
Try to keep the remote close to the appliance but not directly in
front of it. The remote acts as the thermostat.
Remote is placed in the path of
an air draft or vent.
Move the remote away from the direct path of air ow. The
remote acts as the thermostat.
Flame Modulation
The control system is designed to automatically adjust the
ame intensity based on the di󰀨erence between the desired
room temperature, and actual temperature. In thermostat
mode, the hearth appliance will start in HI ame, but as the
actual temperature approaches the desired set temperature
on the remote, the ame intensity will automatically decrease.
Automatic ame modulation will result in more control of the
temperature, and will cause the appliance to cycle OFF/ON
less.
The appliance turns OFF the ame
after extended periods of operation 9 hour safety shutdown timer
This is normal behavior. The appliance has a safety timer that
will automatically turn OFF the ame after nine hours of
uninterrupted operation.
The remote displays the following
message on-screen: Fan will turn
on within 3 minutes
Functioning as intended.
The appliance has a three minute delay timer before the fan is
turned ON. This allows the air surrounding the appliance to be
heated before being pushed into the room.
The remote displays the following
message on-screen:
“Replace remote batteries."
Low batteries in remote. Install new batteries in the remote.
The remote is displaying an
incorrect brand.
Remote was programmed
incorrectly.
Call dealer to have them program the remote with correct
branding. Remote is still fully functional and the appliance is
una󰀨ected.
After turning ame ON using
remote, the ame does not turn
ON immediately and instead a two
minute timer is displayed.
Power vent is installed on the
appliance.
This is expected behavior and the two minute timer is called a
pre-purge timer. The ame will turn ON at the expiration of the
timer.
The remote displays the following
message on-screen:
“Remote Control Communication
Error.”
No power to appliance. Verify home circuit breaker is on and master reset is on (if
equipped).
Power outage. Install new batteries in battery backup.
The remote displays the following
message on -screen: Sorry your
appliance did not start. Try again
by pressing Flame On.
No power to appliance. No gas
to appliance. Accumulation
of air in gas line from extended
period of appliance inactivity.
Gas control system failure.
Verify that appliance has power and gas. Verify that the
appliance accepts ame ON commands with an audible beep,
and successfully turns ame on within 90 seconds. If this failure
persists, contact dealer for service.
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vermont Castings Radiance Series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vermont Castings Radiance Series in the language / languages: English as an attachment in your email.

The manual is 6.69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vermont Castings Radiance Series

Vermont Castings Radiance Series User Manual - French - 46 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info