815507
34
Zoom out
Zoom in
Previous page
1/56
Next page
3434 3-90-30007498Vermont Castings • Radiance RADVT Installation Manual_R32 • 10/23
K. Detailed Component Operating Instructions
- IntelliFire™ Touch
IFT-ECM Detailed Operating Instruction
This model is shipped from the factory equipped with the
IFT-RC400 remote.
1. The Electronic Control Module (IFT-ECM) has a three-
position ON/OFF/REMOTE selector switch that must
be set for proper operation, Figure 4.5. When changing
switch positions, it is important to pause in each position
for 1-2 seconds.
OFF Position:
The appliance will not respond to any commands from
a wired wall switch or IFT-RC400 remote controls. The
unit should be in the OFF position during service, fuel
conversion, and to reset the IFT-ECM in the event the
system goes into a LOCK-OUT mode as the result of a
system error. When switched to the OFF position while
the appliance is operating, the system will shut down.
ON Position:
The appliance will ignite and run continuously at the HI
ame setting. No adjustment in ame height is possible.
Remote Position:
The remote position allows operation of the appliance
from a wired wall switch or IFT-RC400 remote controls.
The IFT-ECM switch must be in this position to pair the
IFT-ECM with the IFT-ACM (if installed), and/or IFT-
RC400 remote controls. See the IFT-RC400 installation
manual for detailed instructions on pairing the IFT-ECM
with the remote controls.
After successfully pairing a IFT-RC400, all installed
accessories can be controlled by the IFT-RC400 (see
IFT-RC400 user manual). The IFT-ECM has a safety
feature that will automatically shut down the replace
after 9 hours of continuous operation without receiving a
command from the IFT-RC400.
The IFT-ECM has a safety feature that will
automaticallyshutdownthereplace after9hours
of continuous operation in the ON position, except
when operated in active thermostat mode.
2. If multiple control options are installed, the IFT-ECM will
respond to the last command from the wired wall switch
or IFT-RC400. The wired wall switch is NOT available if
a Power Vent is used.
3. The Pilot button on the IFT-ECM activates the Cold
Climate function of the replace. This function lights the
pilot ame ONLY to provide enough heat in the rebox
to reduce condensation in cool, high humidity ambient
conditions. To activate the Cold Climate press and hold
the Pilot button for one second and release. The IFT-
ECM will ash two green LED blinks, beep twice and
light and rectify the pilot ame when pressed to activate.
To turn o󰀨 Cold Climate, press and hold the Pilot button
for one second and release. The IFT-ECM will ash one
green LED blink, beep once and shut down the pilot
ame. If remote controls are paired with the IFT-ECM,
this feature can also be activated with the IFT-RC400.
Top View
LED Indicator
3 Position Switch
Figure 4.5 - IFT-ECM
DANGER
Risk of Explosion
DO NOT cycle the ON/OFF/REM selector switch
more than one time within a ve minute period.
Gas may accumulate in rebox. Call a quali ed
service technician.
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vermont Castings Radiance Series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vermont Castings Radiance Series in the language / languages: English as an attachment in your email.

The manual is 6.69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vermont Castings Radiance Series

Vermont Castings Radiance Series User Manual - French - 46 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info