Before You Start
Plan your installation. Set the stove in place and survey how
to best vent the unit. Select the appropriate termination kit
and vent pipe for the installation. Read these instructions
and the stove Owner’s Manual before beginning installation.
After vent conguration has been decided, begin attaching
pipe to unit.
Items required for installation:
Tools:
Hammer Saw and/or saber saw
Level Measuring Tape
Electric drill and bits Pliers
Square
Building Supplies:
Framing materials
Wall nishing materials
Caulking Material (noncombustible)
These models are approved to use HHT direct vent
pipe components, HHT termination kits and DuraVent
components. No other venting system components may
be used.
Horizontal runs must be supported every 3 feet (914 mm)
using wall straps. Vertical runs must be supported every
8 feet (2.4 m) using wall straps. Slip wall straps loosely
on to pipe. Attach straps to framing members using nails
or screws. Tighten nut/bolt to secure pipe.
The stove and venting system should be inspected
before initial use and at least annually by a qualied
eld service person. Inspect the external vent cap on a
regular basis to make sure that no debris is interfering
with the airow. Inspect entire venting system to ensure
proper function.
Outside Wall
Finishing Material
(Vinyl Siding, etc.)
Figure 3.1 - Termination cap on wall
General Information
The Radiance is approved for installation only with the vent
components listed under Section A Venting Requirements
& Options”. Follow the vent component instructions exactly.
For U.S. installations: The venting system must conform with
local codes and/or the current National Fuel Gas Code, ANSI
Z223.1/NFPA 54.
For Canadian installations: The venting system must conform
to the current CSA B149.1 installation code.
Install the starter Pipe
1. Attach the starter to the stove.
2. Place a 3/8” bead of sealant around the inside of the cast
starter collar. Stove cement is provided in the manual
bag for this purpose. Insert the 6-5/8” outer adapter into
the cast outer starting collar and press down rmly.
3. Install the CCSLP Outer Adapter Pipe.
4. Place a 3/8” bead of sealant around the 4” crimped
end of the starter collar on the stove. Stove cement is
provided in the manual bag for this purpose. Attach the
SLP pipe to the adapter, and secure by aligning adapter
and pipe seams, pressing down rmly until pipe stops,
and twisting to lock into place, Figure 3.2.
WARNING
!
Any horizontal run must have a 1/4” rise for every one (1)
foot of run towards the vent termination. Never allow the
vent pipe to run down. This could cause high temperatures
and may present a re hazard.
WARNING
!
Termination cap must be positioned so the embossed
arrow is pointed up.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vermont Castings Radiance Series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vermont Castings Radiance Series in the language / languages: English as an attachment in your email.

The manual is 6.69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vermont Castings Radiance Series

Vermont Castings Radiance Series User Manual - French - 46 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info