When to Suspect a Combustor Problem
The best way to evaluate the performance of your Dauntless
FlexBurn’s combustor is to observe the amount of smoke
leavingthechimney—bothwhenthecombustorhas“lighted-
o󰀨”andwhenithasnot.Followthesesteps:
• Witharegoingandthecombustorproperlyactivatedand
the damper closed to route smoke through it as described
in the Operation Section, go outside and observe the
smoke leaving the chimney.
Then, open the stove damper and once again check the
smoke leaving the chimney.
You should see signicantly more smoke when the stove
damper is open and exhaust does not pass through the
combustor.However,becarefulnottoconfusesmokewith
steam from wet wood. Steam dissipates in the air quickly;
smokedoes not. Remember that a hot stovewith a 2”-3”
established coal bed is required for catalytic combustion to
occur.
Ifthistestindicatesaproblem,considerotherpossiblefactors
as well, such as the weather or a change in the quality of
yourfuel.Inwarmweather,draftisweakerthanitisincolder
winterweather,andrescanburnsluggishly.Small,hotres
are a good solution under these conditions.
Figure 3.8-Inspectthecatalyticcombustor.
Catalyst
Access Door
Also, consider any changes in your operating routine.
Onceyouhaveruledoutanyotherpossible causes for a
decline in performance, inspect and clean the combustor if
necessary. Be sure to protect any surface you use for setting
the stove parts aside.
Inspecting the Combustor
Removeaccessdoorandinnerrebrick.Removethecatalytic
combustor by lifting up and pulling towards you, Figure 3.8.
NOTE
Burning“green”(insu󰀩cientlyseasoned)woodwillresult
in poorer performance than burning properly seasoned
fuel. Reloading with green wood can also thermal shock
the catalyst, resulting in cracking, or the eventual fallout,
of the honeycomb substrate. You may have to run your
stovehotter(moreair)toachieveacceptableperformance
using green or wet wood.
Cleaning the Optional Combustor
1. Check the combustors honeycomb-like catalyst for a
buildup of y ash. If any is evident, take the catalyst
outside and clean it by blowing air gently through it. Do
not push anything through the honeycomb; the combustor
should be cleaned by forcing air through the combustor
toremoveyashusingavacuumorcanofcompressed
air.
2.Inspectthecatalystfordamageordegradation.Although
small hairline cracks will not a󰀨ect performance, the
catalyst should be essentially intact. If the catalyst is
broken in pieces or has sections missing, it should be
removed or replaced. Call your local Vermont Castings
Authorized Dealer for a replacement catalyst.
3.Ifthecatalystisingoodconditionandclean,re-installit
in the stove and replace the refractory access door.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vermont Castings Dauntless FlexBurn at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vermont Castings Dauntless FlexBurn in the language / languages: English as an attachment in your email.

The manual is 8.21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vermont Castings Dauntless FlexBurn

Vermont Castings Dauntless FlexBurn User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info