622292
8
Zoom out
Zoom in
Previous page
1/72
Next page
DVM4200
24.06.2015 ©Velleman nv
8
D
indicator for AC voltage or current
E
PC-LINK
the meter is in the data transmission mode (DVM4100 only)
F
the meter is in the Auto range mode (automatically selects the
range with the best resolution)
G
the meter is in manual range selection mode
H
maximum/minimum data is displayed
I
the meter is in Data Hold mode
J
the meter is in Relative Measurement mode
K
maximum/minimum peak data is displayed
L
sub-display
M
low battery indication
N
the meter is in Continuity Check mode
O
the meter is in Diode Test mode
P
°C°F
μmAV
nµmF
MKΩHz
Measurement units
Q
second function enabled
R
analog bar
S
main display
6.3 Function keys
key
function
Meaning
Ω
Switch between resistance measurement, diode test and
continuity test.
A mA µA
Switch between DC and AC current.
V
Switch between DC and AC voltage.
Switch between °C and °F.
all
Press to enter/exit Data Hold mode.
all
Press and hold for ±2s to start hold after a 6 seconds
time out.
all
Press and hold >2s while switching on the meter to
check LCD. Press again to clear display
all
Press and hold for ±2s to switch the backlight on/off.
all
Press to enable second function (peak mode).
all
Press then press to enter PC-Link mode. Repeat
to exit PC-Link mode.
V, Hz, ,
Ω, A, mA, µA
Press to enter manual ranging mode and to scroll
through the different ranges. Press and hold for ±2s to
return to auto-ranging.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Velleman DVM4200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Velleman DVM4200 in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 1,18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info