Press the SHIFT button followed by the RANGE button, the meter enter PC-Link
mode. T the symbol “PC-LINK” will appear on the LCD [E] and the serial data
output function is active.
Notes:
It is not possible to enter PC LINK during measurement; the meter must be
switched off first.
Run the PC-LINK software, click the SET menu. Select the System Set. Then
select the proper COM port in the Serial Port Select. The COM port is normally
detected automatically. To determine the COM port manually, go to Device
Manager:
Right-click the My Computer icon on the Windows desktop, and then click
Properties.
Click the Hardware tab and then click Device Manager.
Scroll through the list of installed devices and locate the Ports (Com and LPT)
entry. Click the plus (+) next to this entry to view the installed ports, If no
errors occurred, the “Prolific USB-to-Serial COM Port (COM x) will appear, COM
x is the port, with x = a specific number.
Select the default sampling rate or set a desired sampling rate.
Now press the Start in the PC-LINK SOFT to measure and view the real-time data
or graph in the software interface.
To disable the serial data output function, switch the meter OFF or press the
SHIFT button followed by the RANGE button.
More information about the PC-LINK SOFT can be found in the help-file of the
software.
7. Operating instructions
Risk of electric shock during operation. Be very careful when
measuring live circuits.
Before measuring, always make sure the meter and/or test probes are not
damaged and verify the connections, selected function and range.
Never exceed the limit value for protection. This limit value is listed separately in
the specifications for each range of measurement.
Do not touch unused terminals when the meter is linked to a circuit which is being
tested.
Only use the meter in the indicated overvoltage/installation category. Never
measure voltages that might exceed the indicated category values.
When a measuring range is unknown, always select the highest possible range
and lower to the appropriate range.
Disconnect the test leads from the tested circuit before rotating the range selector
in order to change functions.
When carrying out measurements on a TV set or switching power circuits, always
remember that high amplitude voltage pulses at the test points might damage the
meter.
Always be careful when working with voltages above 60Vdc or 30Vac rms. Keep
your fingers behind the probe barriers at all times during measurement.
Do not measure current in circuits with voltages > 1000V.
Never perform resistance, diode or continuity measurements on live circuits. Make
sure all capacitors in the circuit are depleted.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Velleman DVM4200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Velleman DVM4200 in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 1,18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info