3. Diving with Galileo
- If you are breathing from TD, the RBT is
for the decompression calculation that
is actually displayed on the computer
screen.
3.7.7 Logbook for dives with more
than one gas mixture
For dives carried out with more than one gas
mixture, Galileo adds a page in the logbook
for each gas mixture. These appear just
before the page listing warnings and alarms.
Each page shows oxygen concentration,
starting pressure, end pressure, consumed
pressure and, for T2 and TD only, depth at
which the switch took place.
3.7.8 Planning dives with more than
one gas mixture
The dive planner considers all programmed
gas mixtures when computing no-stop
times or decompression schedules. When
more than one gas is set, the symbols T1,
T2 (if applicable) and TD appear on the dive
planner screen.
3.8 Gauge mode
When Galileo is set to gauge mode, it will
only monitor depth, time, tank pressure,
heart rate and temperature, and will not
carry out any decompression calculation.
Maximum displayed dive time in gauge
mode is 99 hours and 59 minutes. You can
only switch to gauge mode if the computer
is completely desaturated. All audible and
visual alarms, other than the low battery
alarm, are turned off.
!
WARNING
Dives in gauge mode are performed at your
own risk. After a dive in gauge mode you must
wait at least 48 hours before diving using a
decompression computer.
When on the surface in gauge mode,
Galileo will show neither the remaining
desaturation time nor the CNS O
2
% value.
It will however display a surface interval up
to 24 hours and a 48 hour no-fl y time. This
no-fl y time is also the time during which you
cannot switch back to computer mode.
The surface display changes as shown
below:
During a dive in gauge mode, the following
information is displayed:
- current depth
- dive time
- tank pressure
- stopwatch
- maximum depth
- temperature
- heart rate
- average depth
68


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for UWATEC Galileo Sol at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of UWATEC Galileo Sol in the language / languages: English as an attachment in your email.

The manual is 2,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of UWATEC Galileo Sol

UWATEC Galileo Sol User Manual - German - 82 pages

UWATEC Galileo Sol User Manual - Dutch - 80 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info