550277
66
Zoom out
Zoom in
Previous page
1/80
Next page
64
3. Diving with Galileo
NOTE:
- Start breathing from the tank
with the new gas mixture before
confi rming a switch.
- If you choose a different tank than
the one suggested by Galileo, the
MOD alarm may go off and the
decompression schedule may
change.
!
WARNING
Always make sure you are switching to the
intended gas. Failure to do so may result in
serious injury or death.
If you confi rm the switch, the message
SWITCH TO GAS T2 (or TD) SUCCESSFUL
appears on the display for 4 seconds. If
you exit without confi rming the switch, the
message EXCLUDING GAS T2 (or TD)
appears for 4 seconds.
3.7.5 Special situations
3.7.5.1 Switching back to a gas mixture
with lower oxygen concentration
There may be situations in which you
have to switch back to a gas with lower
oxygen concentration than what you are
currently breathing. This can happen for
instance if you want to descend deeper
than the MOD for the current gas, or if for
instance you have run out of gas in TD
during the decompression. At this point
you can manually initiate the gas switch
by pressing and holding the left button.
Galileo will display the message SWITCH
TO GAS T1 (or whichever is next in the
sequence) and its MOD. The left and
middle button labels change to SAVE and
>>, respectively. Use >> to choose the tank
you want to use, then press or press and
hold SAVE to confi rm the switch. Galileo
will display the message SWITCH TO GAS
T1 (or T2) SUCCESSFUL and adapt the
decompression schedule accordingly. If you
want to interrupt the gas switch procedure,
press and hold the right button.
3.7.5.2 Gas switch not carried out
at the planned depth
If you fail to confi rm the change of gas mixture
within the 30 seconds of when Galileo
suggested it, the gas mixture in question is
excluded from the decompression calculation
and the decompression schedule is adapted
accordingly.
- If you had programmed 3 gases, you
were on T1 and you did not switch
to T2 when Galileo suggested it, T2
is excluded from the calculations, the
decompression schedule is adapted and
Galileo continues with T1 and TD only.
- If you had programmed 3 gases, you
were on T2 and you did not switch
to TD when Galileo suggested it, TD
is excluded from the calculations, the
decompression schedule is adapted
and Galileo continues with T2 only.
- If you had programmed 2 gases, and
you did not switch to TD when Galileo
suggested it, the decompression
schedule is adapted to refl ect the use of
T1 only.
Galileo alerts you of the change in the
decompression calculation by displaying
the message EXCLUDING GAS T2
(or TD) for 4 seconds.
66


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for UWATEC Galileo Sol at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of UWATEC Galileo Sol in the language / languages: English as an attachment in your email.

The manual is 2,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of UWATEC Galileo Sol

UWATEC Galileo Sol User Manual - German - 82 pages

UWATEC Galileo Sol User Manual - Dutch - 80 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info