550277
67
Zoom out
Zoom in
Previous page
1/80
Next page
3. Diving with Galileo
65
English
NOTE:
If after Galileo has changed the
decompression schedule to refl ect the
missed gas switch, you descend again
below the MOD for the gas mixture you
did not switch to, Galileo reintroduces
that gas into its calculations and the
decompression schedule changes
accordingly. This is accompanied by
the display message INCLUDING T2
(or TD) AGAIN for 4 seconds.
3.7.5.3 Belated gas switch
You can catch up on a planned gas mixture
switch at any time by selecting the gas
manually. Press and hold the left button to
start the gas switch procedure. Galileo will
show the message SWITCH TO GAS T2
(or TD), and its MOD. This helps you verify
that you are performing a switch to a safe
gas. The button labels change to SAVE (left)
and >> (middle). Use >> to choose the next
tank you want to use, then press or press
and hold SAVE to confi rm the switch.
Galileo will display the message SWITCH
TO GAS T2 (or TD) SUCCESSFUL
and adapt the decompression schedule
accordingly. If you want to interrupt the
gas switch procedure, press and hold the
right button.
3.7.5.4 Manual gas switch at a depth
deeper than its MOD
There may be situations in which you have
no other choice but to switch to a different
gas mixture although you are below the
MOD for that mixture. Galileo does not
prevent you from doing this, but the MOD
alarm will immediately go off.
NOTE:
It is not dangerous to switch the
computer to a gas mixture below its
MOD, but rather it is dangerous to
breathe a gas mixture below its MOD.
Galileo alerts you of the imminent
danger when you do so.
3.7.5.5 Submerging below the MOD
after a gas switch
If after having switched to a gas mixture
with a higher oxygen concentration you
inadvertently drop again below the MOD
for that mixture, the MOD alarm will
immediately go off. Either switch back to a
gas mixture suited for that depth, or ascend
above the MOD for the gas mixture you are
breathing from.
3.7.6 RBT when diving with more
than one gas mixture
Galileo determines the RBT based on
your breathing pattern. The tanks with
the various gas mixtures you have with
you may be of different sizes, therefore
the RBT calculation cannot be extended
to all tanks at once since your breathing
pattern will be different for each tank. Since
Galileo performs several decompression
calculations simultaneously for all possible
combinations of gas mixtures, the RBT
calculation references the decompression
calculation that considers only the gas you
are currently breathing from.
- If you have programmed 2 or 3 gases
and are currently breathing from T1,
the RBT will be for the decompression
schedule that considers T1 only.
- If you have programmed 3 gases and
are currently breathing from T2, the RBT
will be for the decompression schedule
that consider T2 only.
67


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for UWATEC Galileo Sol at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of UWATEC Galileo Sol in the language / languages: English as an attachment in your email.

The manual is 2,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of UWATEC Galileo Sol

UWATEC Galileo Sol User Manual - German - 82 pages

UWATEC Galileo Sol User Manual - Dutch - 80 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info