1.3 Nitrox information (O
2
information)
For dives with compressed air in normal recreational diving, nitrogen is the decisive gas for the decompres
-
sion calculations. When diving with Nitrox, the risk of oxygen toxicity rises with the increase of the fraction
of oxygen and the increase of depth and can limit dive time and the maximum depth. Aladin
®
ONE includes
this in the calculations and displays the necessary information:
<O
2
% MIX> Fraction of oxygen: The fraction of oxygen in the Nitrox mixture can be set
with SmartTRAK between 21% (normal compressed air) and 50% in 1% incre
-
ments. Your selected mix will be the basis for all calculations.
ppO
2 max.
Maximum allowed partial pressure of oxygen: the higher the fraction of oxy-
gen in the mixture, the shallower the dive depth at which this value of the
partial pressure of oxygen is reached. The depth at which ppO
2
max. is reached
is called Maximum Operating Depth (MOD).
When you enter the settings for the gas mixture with
SmartTRAK, SmartTRAK
will display
the cor
responding MOD. Aladin
®
ONE
warns the diver
visually once
the depth is reached at which the ppO
2
reaches the maximum allowed value
->15.
The setting of ppO
2
max. is 1.4 bar.
<CNS O
2
> Oxygen toxicity: With the increased percentage of oxygen, the oxygen in the
tissues (especially in the central nervous system (CNS)) becomes important. If
the partial pressure of oxygen rises above 0.5 bar, the CNS O
2
value increases,
if the partial pressure of oxygen is below 0.5 bar, the CNS O
2
value decreases.
The closer the CNS O
2
value is to 100%, the closer the limit where symptoms
can occur ->15.
Nitrox diving may only be attempted by experienced divers after proper training
from an internationally recognized agency.
10
1 Terminology / Symbols
III UWATEC
®
Aladin
®
ONE
CNS O
2
%
increases
ppO
2
Depth
at which ppO
2
reaches 0.5 bar
for three typical mixes
0.5 bar
21% 13m (43ft)
32% 6m (20ft)
36% 4m (13ft)
CNS O
2
%
decreases
0.21 bar
WARNING
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for UWATEC Aladin One at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of UWATEC Aladin One in the language / languages: English as an attachment in your email.

The manual is 1,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of UWATEC Aladin One

UWATEC Aladin One User Manual - German - 24 pages

UWATEC Aladin One User Manual - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info