652332
12
Zoom out
Zoom in
Previous page
1/36
Next page
12
General info
l/min
bar
bar
l
°C
°C
l
bar
l
l
bar
bar
l/min.
l/min.
l/min.
l/min.
l/min.
l/min.
l/min.
°C
V-Hz
A (F)
W
IP
kg
kW
kW
%
%
%
%
n.
%
%
%
°C
g/s
%
%
mg/kWh
%
%
RTN 24
24
10,17
90,57
89,76
92,60
87,14
2
92,85
90,83
2,38 - 2,28
86,7
14,11-20,03
117,89
2,9-5,1
152,4
2
9,17 - 7,15
0,831
RTFS 24
24,2
9,9
91,34
89,77
89,93
87,15
2
92,71
87,81
1,7-1,37
116,7
13,41-15,1
60,86
3,0-7,0
184,4
2
12,19-7,29
0,405
CTN 24 F
24
10,17
90,57
89,76
92,60
87,14
2
92,85
90,83
2,38 - 2,28
86,7
14,11-20,03
117,89
2,9-5,1
152,4
2
9,17 - 7,15
0,831
CTFS 24 F
24,2
9,9
91,34
89,77
89,93
87,15
2
92,71
87,81
1,7-1,37
116,7
13,41-15,1
60,86
3,0-7,0
184,4
2
12,19-7,29
0,405
CTN 24
24
10,17
90,57
89,76
92,60
87,14
2
92,85
90,83
2,38-2,28
86,7
14,11-20,03
117,89
2,9-5,1
152,4
2
9,17-7,15
0,831
RTN 24
II
2H3P
7,3
0,7
3
3,5
78
45
6
1
137,9
-
-
-
-
-
-
-
-
-
-
230/50
3,15
96
X4D
28
31
CTN 24 F
II
2H3P
7,3
0,7
3
3,5
78
45
6
1
137,9
2,5
0,5
6
11,5
12
7,6
8,6
9,8
11,4
13,7
35 - 57
230/50
3,15
96
X4D
30
33
CTFS 24 F
II
2H3P
7,10
0,7
3
3,5
78
45
6
1
137,9
2,5
0,5
6
11,5
12
7,6
8,6
9,8
11,4
13,7
35 - 57
230/50
3,15
130
X4D
36,5
39,5
RTFS 24
II
2H3P
7,10
0,7
3
3,5
78
45
6
1
137,9
-
-
-
-
-
-
-
-
-
-
230/50
3,15
130
X4D
34,5
37,5
CTN 24
II
2H3P
7,3
0,7
3
3,5
78
45
6
1
137,9
2,5
0,5
6
11,5
12
7,6
8,6
9,8
11,4
13,7
35 - 57
230/50
3,15
98
X4D
32
35
EVE 05
CTFS 24
II
2H3P
7,10
0,7
3
3,5
78
45
6
1
137,9
2,5
0,5
6
11,5
12
7,6
8,6
9,8
11,4
13,7
35 - 57
230/50
3,15
132
X4D
38,5
41,5
CTFS 24
24,2
9,9
91,34
89,77
89,93
87,15
2
92,71
87,81
1,7-1,37
116,7
13,41-15,1
60,86
3,0-7,0
184,4
2
12,19-7,29
0,405
Warning:If the boilers are used in low tem-
perature heating system (ex. floor hea-
ting)
it is necessary to use a mixing valve to
avoid condensation phenomena.
1.4 - OPERATING DATA
Nominal output
Minimum output
Actual water efficiency at full load (100%)
Min. required water efficiency at full load (100%)
Actual water efficiency at part load (30%)
Min. required water efficiency at part load (30%)
Stars No. off (According EEC Directive 92/42)
Combustion efficiency at nominal load (100%)
Combustion efficiency at part load (30%)
Stand-by losses (min.-max.)
(*)Flue gas temperature (min. - max.)
Flue gas mass flow rate (min. - max)
Excess of air l
CO
2
NO
X
(value according EN 297/A3 + EN 483)
NO
X
class
Flue losses with burner in operation (min.-max)
Flue losses with burner off
For the following data: Nozzle - Burner pressure - Diaphragm (where applicable) - Inputs - Gas consumptions refer to pagraph SUITABILITY TO USE
OTHER GASES.
Appliance category
Min. water flow rate in CH circuit (Dt 20 K)
Min. pressure in CH circuit
Max. pressure in CH circuit
Water content primary circuit
Max. oper. temperature in CH mode
Min. oper. temperature in CH mode
Total capacity of expansion vessel
C.H. expansion vessel pre-loading
Max. water content CH circuit (calc. x max. T°of 82°C)
Min. water flow rate in D.H.W. circuit
Min. DHW. pressure
Max. DHW. pressure
DHW specific flow rate (Δt 30 K)
Flow restrictor
DHW production in continuous operation with Δt 45 K
DHW production in continuous operation with Δt 40 K
DHW production in continuous operation with Δt 35 K
DHW production in continuous operation with Δt 30 K
DHW production in continuous operation with Δt 25 K*
DHW Temperature range
Electrical supply
Supply fuse
Maximun absorbed power
Insulation protection
Net weight
Gross weight
1.5 - GENERAL FEATURES
(*) mixed
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Unical EVE 05 RTFS 24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Unical EVE 05 RTFS 24 in the language / languages: English as an attachment in your email.

The manual is 1,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info