765111
34
Zoom out
Zoom in
Previous page
1/39
Next page
33
CALIBRATION PROCEDURE
1. Remove the safety key
2. Press and hold down the Start and Fast
+ buttons and replace the safety key.
Continue to hold the
Start and
Fast key until the window displays “Factory settings press
enter”, then press the
Enter key.
3. You will now be able to set the display to show Metric or English settings (Miles vs. Kilometers).
To do this, press the up or down key to show which you want, then press
Enter.
4. Make sure the wheel size diameter is 3.01 then press
Enter
5. Adjust the minimum speed (if needed) to 0.5 mph /1.0 kmph and then press
Enter
6. Adjust the maximum speed (if needed) to 12.0 mph / 18.0 kmph and then press
Enter
7. Adjust the maximum elevation (if needed) to 15 and then press
Enter
8. Grade return – On (This allows the incline to return to zero when
Stop is pressed on training)
9. Press
Start to begin calibration. The process is automatic; the speed will start up
without warning, so do not stand on the belt.
ADJUSTING THE SPEED SENSOR
If the calibration does not pass you may need to check the speed sensor alignment.
1. Remove the motor cover hood by loosening the 4 screws that hold it in
place (you do not need to remove them completely).
2. The speed sensor is located on the left side of the frame, right next to the
front roller pulley (the pulley will have a belt around it that also goes to the
motor). The speed sensor is small and black with a wire connected to it.
3. Make sure the sensor is as close as possible to the pulley without
touching it. You will see a magnet on the face of the pulley; make sure
the sensor is aligned with the magnet. There is a screw that holds the
sensor in place that needs to be loosened to adjust the sensor.
Re-tighten the screw when finished.
MAINTENANCE MENU
1. Press and hold the
Start, Stop and
Enter key at the same time, until the display shows “Engineering
mode” (it may say maintenance menu, depending on version). Press the
Enter key.
2. You can now scroll through the menu using the + and - keys. Use the
Stop key to return to previous
menu selection. The menu selections are:
A. Key Test - Tests that each key is functioning properly
B. Display test - Test the LCD display segments are all lighting properly
C. Functions
I. Sleep Mode - Allows you to turn off the sleep mode. Console will stay on all the time unless
power is turned off.
II. Pause Mode - When the console is paused during a program this will allow you to keep the
console paused indefinitely instead of 5 minutes.
III. Odometer reset- Allows you to reset the odometer
IV. Unit Metric- When enter is pressed allows you to change the settings for data to metric.
V. Motor Test - For service personnel only when troubleshooting motor problems.
VI. Beep - Allows you to disable the speaker so there is no beeping.
VII. Grade return - When in Pause mode the incline will return to zero automatically.
D. Security - Allows you to lock the keypad so the treadmill cannot be used. Press Enter to change
setting (also called child lock).
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for U.N.O. TR 4.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of U.N.O. TR 4.0 in the language / languages: English as an attachment in your email.

The manual is 2,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of U.N.O. TR 4.0

U.N.O. TR 4.0 User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info