631208
10
Zoom out
Zoom in
Previous page
1/16
Next page
Insert heater with cowl body (1) through the wall cut-out (2),
allow approx. 5 mm to project out of the wall. Mount sealing
frame (3) (the anti-twisting device ensures correct fitting!).
Pre-drill holes for the 6 fastening bolts (4).
4
1
3
2
Remove sealing frame (3) and coat with non hardening mastic
on the side facing the vehicle – do not use silicone!
The sealing frame must be well sealed with respect to
the front sides and the cross bars of the cowl body (1)
as well as towards the outside wall!
Fasten sealing frame (3) to the cowl body using 4 self-cutting
screws (4).
4
3
Screw the sealing frame (3) in contact together
with the cowl body (1) so the anti-twist device
projects out!
9
7
4
6
1
3
5
8
Seal the gap between the hole (6) and the condensation
tube (7) with non hardening mastic – do not use silicone!
Mount the grille (8). Press the entire cowl assembly onto the
vehicle wall and fasten with 6 screws (5).
Screw the water heater securely to the floor of the vehicle
with at least two shackle plates (9) with the screws provided,
B 5.5 x 25, on suitable base (plywood panel, laminated wood
strips or metal base).
Water connection
All pressure and submergible waterpumps up to 2.8 bar
and all mixed combination sets with or without an electrical
switch, can be used for operating the water heater.
If connecting to a central water supply (rural or city con-
nection) or when using more powerful pumps, a pressure
reducer must be used which prevents pressures of greater
than 2.8 bar occurring in the system.
When using submergible pumps, a non-return valve (10 – not in-
cluded in the scope of supply) must be fitted between the pump
and the first branch point (arrow points in direction of flow).
10
13
12
14
When using pressure pumps with high switching hysteresis,
hot water may flow back through the cold water tap. To pre-
vent the backflow, we recommend that a non-return valve
(11 – not included in the scope of supply) be fitted between
the outlet to the cold water tap and the drain valve.
14
11
13
12
When using the Truma Ultrastore together witch the
Truma Ultraflow pressure switch, the use of a non-re-
turnvalve is essential (please refer to the pressure switch
instruction).
In order to guarantee complete emptying of the water
content and ongoing sealing tightness of the water
connections, the enclosed water connectors (12 + 13) and
the safety (pressure relief) drain valve (14) must be used!
John Guest System rigid pipe routing
The water connectors (12 + 13) and safety/drain valve (14)
supplied with the Truma Ultrastore have a 12 mm diameter
fitting and are only approved to use with Original John Guest
piping.
For connecting to rigid pipes with other diameters appropiate
adapters (not included in scope of delivery) must be used.
10
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Truma Ultrastore Rapid GE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Truma Ultrastore Rapid GE in the language / languages: English as an attachment in your email.

The manual is 1,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info