Choice of location
Always install the appliance in such a way that it is easily
accessible for service work at all times and can be easily
removed and installed.
Locate the heater in such a way that the cowl can be mounted
on the outside on a surface which is as straight and smooth
as possible. This outside surface must be exposed to wind
from all directions and, if possible, there should be no trim
strips or covers in this area, mount heater on an appropriate
base, if necessary.
The cowl may not be positioned within 500 mm (A) of a refu-
elling point or fuel tank breather outlet or within 300 mm (A)
of a ventilator for the living space. If the cowl is positioned
vertically below an opening part of a window, the water heater
must be fitted with an automatic shut-off device (please refer
to page 14) to prevent operation when the window is open.
Window
Floor
300 mm
300 mm
Prohibited
Zone
Prohibited
Zone
A
The heater must not be installed close to or directly behind a
room / space heater.
To achieve reasonable air flow for electronics cooling,
there should be a minimum distance of 20 mm between the
electronics cover (34) and the walls of the furniture piece
the Ultrastore is located in.
Installation of the water heater
Position template for cowl opening on the inside of the wall.
A = bottom edge of heater
B = lateral edge of heater
Drill 4 holes (C) with 10 mm dia. through the wall. Drill hole (E)
with 15 mm dia. for condensation pipe (also possible from the
outside = F).
Position template on the outside of the wall. The markings (C)
must be above the through-holes. Saw cut-out section for
cowl (D) 92 x 168 mm.
If the distance between outside wall and heater is more than
35 mm you must use the cowl extension VBO 2 (please refer
to page 14) with an additional length of 50 mm. Saw out
100 x 176 mm along the dashed line.
A
rea cut-away
for clarification
If there are any cavities in
the area of the cowl, pack
these with pieces of wood
so as to be able to tighten
the screws. The finished
hole should be 168 mm high
and 92 mm wide.
Cut out trim strips or such on the vehicle or place supports
beneath them so as to make the cowl lie flat.
Place a support beneath the heater if the walls are sloping.
An angle of inclination of 10 degrees is not to be exceeded.
Installation instructions
Installation and repair are only to be carried out by an
expert. Always read and follow the operating instructions
carefully prior to starting any work!
Non-compliance with installation instructions or
incorrect installation can result in endangerment
of persons and property.
Intended use
This appliance has been designed for the installation in cara-
vans, motor homes and other vehicles. It is not approved
for installation in boats. Other forms of use are also possible
following consultation with Truma.
Information regarding boats: For installation in boats Truma
supplies the DVGW-tested boat water heater.
Regulations
Any modifications to the unit (including the exhaust duct and
the cowl) or the use of spare parts and accessories that are
important to the operation of the system (e.g. the time switch)
that are not original Truma parts and failure to follow the in-
stallation and operating instructions will cancel the warranty
and indemnify Truma from any liability claims. It also becomes
illegal to use the appliance, and in some countries this even
makes it illegal to use the vehicle.
In-vehicle installations must comply with the technical and
administrative regulations of the respective country of use
(e.g. EN 1949 for vehicles). The national regulations and rules
must be complied with.
Water heater kit
The water heater kit contains
1 Assembled water heater
1 Cowl assembly with screws
1 Hot water connector
1 Cold water connector
1 Safety (pressure relief) drain valve
1 Wall switch (gas operation) with 3 m cable
1 Wall switch (230 V operation)
1 Installation template
1 Set literature
1 Label with warning information
In order to guarantee complete emptying of the water con-
tent, ongoing sealing tightness of the water connections and
safety function all enclosed parts must be used!
9
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Truma Ultrastore Rapid GE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Truma Ultrastore Rapid GE in the language / languages: English as an attachment in your email.

The manual is 1,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info