Gas connection
Figure 13
The operating pressure of the gas supply is 30 mbar
and must be the same as the operating pressure of the
device (see type plate).
The 8 mm diameter gas supply pipe must be attached to the
connection (38) using an olive connection. The olives must be
selected according to the gas supply pipe used (for copper
pipes: brass insertion sleeves and olive included in scope of
delivery). Carefully counterhold with another wrench when
tightening.
Before connecting to the boiler, ensure that the gas lines are
free of dirt, swarf and the like.
The pipes must be installed in such a way that the device can
be removed again for service work.
The number of separation points in the gas supply line in
rooms used by persons must be limited to the technical
minimum.
The gas system must comply with the technical and admin-
istrative regulations of the respective country of use (e.g.
EN 1949 for vehicles). National regulations and rules must be
followed.
Control panel installation
Make allowance for the length of the connector cable (3m)
when choosing a location. A 5m cable extension is available
if necessary.
Ø 55 mm
29
28
33
33
32
26
31
28
25
Figure 14
If the control panels cannot be flush-mounted, Truma can
provide an on-surface frame (25 – part no. 40000-52600)
as an accessory by request.
Drill a hole with a diameter of 55mm.
Connect the control panel cable (28) to the control panel (26)
and then connect the rear blank cover (29) as strain relief.
Push the cable through towards the rear and route the con-
nector cable (28) to the boiler.
Route the connector cable with the connector (28) to the 12V
electronic control unit (for connection, see “12V electrical
connection”).
Secure the control panel with 4 screws (31).
Fit the front cover (32).
Truma supplies side parts (33) as accessories to improve
the appearance of the cover frames. Please contact your
dealer.
12
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Truma BGF 10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Truma BGF 10 in the language / languages: English, German, Dutch, Danish, French, Italian, Swedish as an attachment in your email.

The manual is 5,69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Truma BGF 10

Truma BGF 10 User Manual - English, German, Dutch, Danish, French, Italian, Swedish - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info