Technical data
Power supply
230 V – 240 V ~, 50 Hz
Current consumption
Cooling: 4.2 A
Heating: 3.7 A
Start-up current
28 A (150 ms)
Cooling power
2.4 kW
Heating power
1.7 kW (heat pump)
Volumetric air flow
Max. 400 m³/h
Operational limits
+4 °C to 40 °C
Maximum tilt during operation
8 %
Weight
33.5 kg plus installation materials
Dimensions (W x H x D)
External: 660 x 248 x 1008 mm
Internal: 523 x 46 x 670 mm
Refrigerant
R 407C
Refrigerant content
See type plate on unit
Installation dimensions (dimensions in mm)
670
1008
248
46
25 - 110
400
(380)
400
(350)
523
195
(215)
530
660
Troubleshooting
Fault Cause / Action
Unit not cooling Thawing process in progress
The temperature set on the re-
mote control has been reached
or is too high
Unit not heating Thawing process in progress
(outside temperature between
4 °C and 7 °C)
Outside temperature below 4 °C
Unit underperforming
or failing in cooling /
heating mode
Filter soiled, replace filter
Air ways to the outside soiled /
blocked
Moisture on the un-
derside of the air
distributor
Close windows and doors and
set the fan level to high
Water dripping out of
air distributor
Condensation trap on external
unit blocked
No proper seal between unit
and roof (e.g. faulty seal)
Angle of tilt of system too great
Remote control not
working
Check remote control batteries
and replace if necessary
Unit not responding
to remote control
commands
Check for obstructions between
remote control and IR receiver
Should these actions not resolve the corresponding
problem, please contact Truma Service.
18


Need help? Post your question in this forum.

Forumrules
1

Forum

truma-aventa-comfort

Reset search

  • Truma aventa making clicking noise. Other than the noise, which gets louder with use, the unit works perfectly. Has anyone else had this problem?
    Bev Submitted on 7-4-2023 at 08:16

    Reply Report abuse
  • My truma aventa is making a ticking noise. Has got a solution due this problem. The unit works perfectly otherwise Submitted on 7-4-2023 at 08:13

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Truma Aventa comfort at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Truma Aventa comfort in the language / languages: English, German, Dutch, Danish, French, Italian, Spanish as an attachment in your email.

The manual is 3,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info