756394
16
Zoom out
Zoom in
Previous page
1/33
Next page
16 EN
thermal imaging camera XC300 / XC600
Switching the laser pointer on or off
The integrated laser can be used as both a pure aid to
orientation and for aiming and a means to exactly measure the
distance between the IR camera and the object to be
thermographed.
Please proceed as follows to switch the laser pointer on or off:
Warning of laser radiation
Laser class2, Pmax.: <1mW, λ: 400-700nm,
EN60825-1:2014
Do not look directly into the laser beam or the opening
from which it emerges.
Never point the laser beam at people, animals or
reflective surfaces. Even brief eye contact can lead to
eye damage.
Examining the laser output aperture by use of optical
instruments (e.g. magnifying glass, magnifiers and the
like) entails the risk of eye damage.
When working with a laser of class2, observe the
national regulations on wearing eye protection.
üThe protective cover of the laser pointer(8) is opened by
swivelling it to the side by 180°.
1. Press the C button(17) on the control panel(2) or tap the
Trotec logo on the display(1).
ðThe main menu is displayed on the left-hand side of the
display.
2. Select the Settings menu.
3. Select the System menu.
4. Select the Control option.
5. Activate the laser permanently by sliding the selector
switch on the display to the right.
ðThe laser pointer is switched on and pulsates at regular
intervals.
ðThe Laser selector switch is highlighted in blue(ON).
ðAdditionally, a red cursor is displayed to mark the
target.
6. Deactivate the laser permanently by sliding the selector
switch on the display to the left.
Please observe that the integrated laser does not only
constitute a pure means for aiming or an aid to orientation,
but that it can also be utilized for carrying out an exact
measuring of the distance to the measuring object. If you
have programmed the laser function to the multifunction
button(5), you can activate or deactivate the laser by
pressing this button. Further information on the
multifunction button is provided in the chapter Configuring
the multifunction button. In the active state, the laser
pulsates at regular intervals, measuring the distance from
the camera to the measuring object in each case. You do
not have to press the trigger to carry out this process. The
distance measured is displayed at the lower right end of
the LCD screen and is also automatically updated in the
Global Parameters menu item.
7. Close the protective cover of the laser pointer(8).
Info
When the laser is not active, the distance to the
measuring object must be entered manually to obtain
measurement results that are as precise as possible.
Using the AV port
You can connect the device to a screen via an AV cable. The
image can be transmitted in PAL or NTSC format.
1. Press the C button(17) on the control panel(2) or tap the
Trotec logo on the display(1).
ðThe main menu is displayed on the left-hand side of the
display.
2. Select the Settings menu.
3. Select the System menu.
4. Select the Control menu.
5. For the option TV-Out Mode select the desired format PAL
or NTSC.
6. Enable the TV-Out option by sliding the selector switch to
the right.
ðThe TV-Out selector switch is highlighted in blue (ON).
ðThe TV output is activated.
7. Open the sealing cap at the AV output(3).
8. Schließen Sie das beiliegende bzw. ein geeignetes
AV-Kabel am Gerät an und verbinden Sie es mit dem
Bildschirm.
Switching the device off
1. Press and hold the Power button(13) for approx. 3s.
2. Confirm the prompt with OK.
ðThe message "power off" is displayed and the camera
switches off after a few seconds.
3. Close the display(1).
4. Fix the protective cap to the IR lens(10).
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec XC600 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec XC600 in the language / languages: English as an attachment in your email.

The manual is 9,47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec XC600

Trotec XC600 User Manual - German - 33 pages

Trotec XC600 User Manual - Dutch - 32 pages

Trotec XC600 User Manual - French - 33 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info