Power supply wiring
Item
Model
Wire size
All models of indoor units 2.0 mm² Max. 20m 3.5 mm² Max. 50m
[Indoor unit]
NL
Earth
NL
Earth
NL
Earth
NL
Earth
Earth leakage breaker
Indoor unit
Connection cable
Connector conversion cable
(MMK-AP∗∗∗2H (High Wall) does not use a this conversion cable.)
Indoor control P.C. board
Pulse motor valve (Indoor unit side)
CN82 connector
Pull box
Main switch
Indoor unit power supply
1N~ 50Hz, 220 240V
1N~ 60Hz, 220V
PMV
PMV Kit
For Indoor unit power supply (The outdoor unit has a separate power supply.)
Note)
Power supply cord specification : Cable 3-core 2.5 mm², inconformity with Design 60245 IEC57.
The connecting length indicated in the table represents the length from the pull box to the outdoor unit when the
indoor units are connected in parallel for power, as shown in the illustration below. A voltage drop of no more than
2% is also assumed. If the connecting length will exceed the length indicated in the table, select the wire
thickness in accordance with indoor wiring standards.
Determine the wire size for indoor unit according to the number of connected indoor units downstream.
For details of the PMV Kit, refer to the Installation Manual.
Connection of PMV Kit
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Toshiba MCY-MAP0401HT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Toshiba MCY-MAP0401HT in the language / languages: English, German as an attachment in your email.

The manual is 2,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info