587680
24
Zoom out
Zoom in
Previous page
1/81
Next page
21
Power supply specifications
Select the power supply cabling and fuse of each outdoor unit from the following specifications.
Ensure an earth leakage breaker is installed, failure to install, may result in electric shock.
The installation fuse must be used for the power supply line of this outdoor unit.
Be sure to use the appropriate type of overcurrent breaker (fuse) switch.
Observe local regulation regarding wire size selection and installation.
3-core cable in conformance with Design 60245 IEC 66.
Do not connect the units looping via the terminal blocks (L, N).
Outdoor unit
capacity type
0401 type
0501 type
0601 type
Wire size*
6 mm², Max. 28 m
6 mm², Max. 25 m
6 mm², Max. 22 m
Maxim running
current
25A
28A
31A
Installation
fuse
32A
32A
40A
Over current breaker (fuse) switch
Outdoor unit
Outdoor unit power supply
Earth leakage breaker
Earth
LN
* Design 60245 IEC66
(Terminal block) (Stripping length power cable)
(Cord clamp)
(Protective bush : Accessory)
Power cable
NL
10
LN
10
50
90
Earth line
Power cable
Power
supply
MCY-MAP###HT series
MCY-MAP###HT2D series
1N~ 50Hz 220V-240V
1N~ 60Hz 220V
(Connection example)
Connection of power supply
n Power supply wire
Connect the power supply cables and earthling wire to the power supply terminal block.
Tighten the screws on the terminal block and secure the cables with the cord clamp.
(Do not apply tension to the connecting section of the terminal block.)
4
ELECTRIC WIRING
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Toshiba MCY-MAP0401HT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Toshiba MCY-MAP0401HT in the language / languages: English, German as an attachment in your email.

The manual is 2,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info