Menu stage 5: opening force limit
Menu stage 6: closing force limit
15a
15b
If you previously quit the setting menu, press and
hold button for 3 seconds until "3" is displayed.
Then press button twice until "5" is displayed.
After approx. 2 seconds the display flashes showing
the set value of the force limit for the opening phase.
The factory setting is "6".
The force limit setting can be increased or decreased
via the and buttons. After selecting the setting,
press button . "6" is displayed.
After approx. 2 seconds the display flashes showing
the set value of the force limit for the closing phase.
The force limit setting can be increased or decreased
via the and buttons.
Finally, check the force settings and, if necessary,
repeat the setting procedure.
The force at the main closing edge must not exceed
the values specified in DIN EN 12453. Depending on
how the gate is used and the need to consider
national regulations, it may be necessary to
introduce protective measures over and above this.
If the force is set too high, this can result in
injury to persons or damage to property.
The factory setting is 4, if a higher setting is
selected, proof must be furnished that the
forces are being observed.
After setting the value, press button . “0” is
displayed.
- Position the force measuring device in the
closing area.
(If no measuring device is available, use, for
example, the operator's cardboard box).
- Start the gate from the open position.
- The gate travels towards the obstruction, stops
and reopens.
If alterations were made to the gate, then the force-
learning procedure must be repeated: Call up menu
stage 5 and keep the button pressed for 3
seconds. "0" is displayed. Then carry out force-
learning operations as explained under point
Briefly press button . "1" is displayed.
As soon as the display starts to flash, keep the button
of the hand transmitter, with which you would later
like to start the operator, pressed for approx. 1
second.
As soon as the code has been read in, the red
incremental display (a) flashes five times to
acknowledge it.
Further hand transmitters (up to a max. of 10 button
codes) can be programmed.
Press button . "2" is displayed.
Note: If no partial opening function is to be
programmed, press button once again .
"0" is displayed indicating that the programming is
completed. Press the second button on the hand
transmitter with which partial opening is to be
switched on .
As soon as the code has been read in, the red
incremental display (a) flashes five times to
acknowledge it.
After the code has been learned, briefly press button
. . "0" is displayed. End of menu.
Plug operator into mains whilst keeping button
pressed.
Checking the force limit device
10.
Menu stage 1: programming the starting
function for the hand transmitter
Menu stage 2: programming the partial
opening function for the hand transmitter
15b
Deleting all the hand transmitters programmed
for the operator:
11
12
13
14
15
Special Settings
Menu stage 7: light phases for the signal light
Automatic closing
Keep button pressed for 3 seconds. "3" is
displayed. Press button repeatedly until menu
stage 6 is displayed.
Keep button pressed for another 3 seconds until
"7" is displayed.
Menu Light Advance warning Flashing
value phase phase function
0 - - yes
1- --
2 60 s - yes
360s - -
4 - 3 s yes
5-3s-
6 60s 3s yes
7 60s 3s -
8 - 10 s yes
9-10s-
The setting can be altered via buttons and . The
factory setting is "0". Press button to end the
menu.
3
Cancellation of hold-open phase by
photocell
The functions are described in the operating
instructions.
Menu stage 8: Soft runs
Menu stage 9: Special functions
Normal operation
OPEN-CLOSE operation
operation with single-lane control
Automatic closing
Automatic closing
Menu stage “A”: hold-open phases
Press button . "8" is displayed.
Menu Start Stop Start Stop
value Open Open Close Close
0 0000
1 15 0 15 0
2 0 15 0 60
3 15251560
4 15151560
5 15601560
6 15151515
7 15251585
8 15601585
9 only soft run
Press button . “9” is displayed.
Menu Operating mode
0
(standard setting ex factory)
1or
1
(only together with traffic light control)
External safety device
Photocell required
2
External safety device
Photocell required.
Set hold-open phase in menu stage A
4
Cancellation of the hold-open phase by the
impulse generator
Press button . “A " is displayed. These phases can
only be set for the menu values 2, 3 or 4 set under
menu stage “9”.
Menu Hold-open phase
value (plus 10s flashing as advance warning)
00s
110s
230s
360s
490s
5 120 s
6 150 s
7 180 s
8 210 s
9 240 s
Before initial operation, test the function and safety
of the operator.
All the requirements regarding the safe operation of
the system must be met.
In the case of systems accessed by the public or
used in the automatic closing mode, a photocell must
be installed.
It is recommended that a warning light be installed.
IIn the closing phase the force when distance
X is less than 500mm may not exceed 400N;
X is greater than 500mm may not exceed
1400N.
This is achieved by using safety profiles:
up to 400kg tormatic 35/ 50
up to 400kg tormatic 35/ 70
up to 400kg ASO GE 365
up to 400kg Gelbau 003.10
up to 400kg Mayser GP50
up to 200kg ASO GE 245
up to 200kg Bircher EPE36/45
up to 200kg Gelbau 016.10
Further insertable profiles can be obtained from the
manufacturer on request.
Because of the force limit device integrated into the
operator, the main closing edge may only be
equipped with a passive rubber profile (without
evaluation function).
The safety distances are adhered to if:
x is greater than 500mm or
y is less than100mm and X greater than 200mm
If the safety distances cannot be adhered to, then
this area can be safeguarded either by using a
protective fence or by applying a force limit.
In the case of a force limit, the rear closing edge must
be safeguarded by a safety profile as is the case with
the main closing edge.
Additionally, the distance of the STOP-OPEN soft
run must be correspondingly extended. (Menu 8
value 3 or 5).
If secondary closing edges form, these must be
equipped with safety profiles
up to 300kg tormatic 35 / 50
up to 400kg tormatic 35 / 70
Other profiles used a resistor for terminating voltage
of 8k2.
If access to the gate is safeguarded by fencing, the
maximum opening width A has to be adjusted to
distance X.
X l 120mm less than 18,5mm
X less than 300mm less than 29mm
X less than 500mm less than 44mm
X less than 850mm less than18,5mm.
Safe operation of the gate system
Main closing edge 16a
Gate weight Manufacturer Type
Rear closing edge 16b
Main closing edges 16c
gate weight manufacturer type
Protective fence 16d
Distance Opening size A
16
GB
Retain these installation, operating and maintenance instructions for the full duration of the operator’s service life!
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tormatic NovoGate at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tormatic NovoGate in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 1,18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info