6. Gas technical details
Gas category: Natural gas or Butane/Propane. Type :C11 / C31. Safety: Thermo - electrical
* Nominal output depends on duct situation used.
7. Concentric duct system
The concentric duct system consists of a inner duct, 100 mm in diameter, and a outer duct, 150 mm in
diameter. These ducts are fitted concentrically; discharge of combustion gas is through the inner duct
and supply of combustion air to the appliance is between the inner and outer ducts. The wide range of
elements enables a flexible connection between appliance and outlet section. Various connections are
possible using the concentric duct system:
Through the roof surface and Through the exterior wall.
The route for this system can be constructed in various ways, but there are a number of important
conditions:
Horizontal duct length for roof outlet must be no more than 4 metres, measured between the
bends.
Total maximum duct length permitted is 12 metres (sum of duct length + nominal lengths of the
bends).
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thermocet N21- INTIMO TWO TONE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thermocet N21- INTIMO TWO TONE in the language / languages: English as an attachment in your email.

The manual is 6,48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info