5. Installation instructions
General
The appliance is a completely sealed construction, which is to say that it can be used in chink-free, me-
chanically ventilated homes, without additional ventilation being required. The special concentric duct
system enables the natural discharge of flue gas and supply of combustion air from and to the appli-
ance. Various forms of outlet and routing are possible with this venting system, so that the positioning
of the appliance is flexible.
Attention
* The appliance should be installed, connected and inspected by a registered installer in accor-
dance with national and regional norms.
* The appliance should be inspected by the installer for gas tightness to gas products and combus-
tion products and for correct operation of the various components and functions.
* The venting system and the outlets in the exterior wall or roof surface must comply with the regu-
lations currently in force.
* The appliance is classified as a sealed appliance installed in a location without ventilator and with
a chimney loss in excess of 17% (non-condensing).
* To maximise the heat output of your fire when it is built-in a wall or surround, you can use the op-
tional convection set consisting of 2 ducts, grills and brackets.
Clearance to combustibles
* From the front and sides of the stove a clearance of 500 mm should be taken to curtains, drapes
and other Fabrics
Clearance to non-combustibles
* Construction materials for surround and mantels must be made of non-combustible material.
Attention: this include floor and ceiling
* When installing the appliance, you must maintain a minimum clearance of 20 mm from the wall at
all times.
Maintenance
* The appliance can be cleaned with a soft damp cloth. The appliance should be turned off immedi-
ately if something is spilled on it. The marks can be removed with mild soapy water once the ap-
pliance has cooled down. NEVER use an abrasive!!!
* Any deposit on the glass can be removed with glass cleaner.
* It is advisable to have the fire and the chimney checked and cleaned by an installer before every
heating season. If the special glass is broken or cracked, have it replaced immediately before you
turn the stove on again. In the heating season it is advisable to leave the pilot light on against
condensation in the appliance. If the stove will not be used for a longer period it would be wise to
shut off the gas gas-valve in the supply pipe.
Connection to the gas pipe
Ensure that the control equipment does not become twisted during connection and that no excessive
tension develops. Check the connections for gas tightness after installation. Connect the supply pipe at
the gas-valve with a 3/8” coupling and make sure that the gas pipe is free of dirt and sand.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Thermocet N21- INTIMO TWO TONE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Thermocet N21- INTIMO TWO TONE in the language / languages: English as an attachment in your email.

The manual is 6,48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info