688849
20
Zoom out
Zoom in
Previous page
1/40
Next page
Energy 2510 B
Vers. 002
GB
20
has inexplicable behavior or the display shows
characters without any logic).
6.6 Control panel alarm causes and resetting
During generating set use, alarm signals may be
displayed referring to engine oil checks. After
checking the engine oil, the control panel must
be reset in the following way:
Alarm: the red ‘service’ light is flashing.
Cause: 50 hours have elapsed since the latest
engine oil change and oil level should be
checked.
How to reset the alarm: with panel turned off,
press the partial counter key (Fig.30 Ref.9) and
while holding it down, turn the panel on and re-
lease the push-button when the unit has started
up
Alarm: the red ‘service’ light is lit.
Cause: 100 hours have elapsed since the latest
engine oil change and engine oil should be
changed.
How to reset the alarm: turn on the panel and
wait for the generating set to start. Now press the
button hidden under the small hole in the bottom
left corner (Fig.30 Ref.10) and release it immedi-
ately thereafter. Wait a couple of minutes before
turning the generating set off.
Alarm: the display unit shows random charac-
ters.
Cause: malfunctioning due to low voltage during
start-up (low battery, cable cross-section too
small). In this case, just turn Off and On the con-
trol panel.
In certain situations, data of internal microproc-
essor of the panel may be subject to permanent
alterations and prevent running of generating set.
In this case, to restore the functionality of panel is
necessary to completely re-initialize (contact the
Service).
6.7 Automatic Version (optional)
If you wish the start-up batteries to be recharged
automatically in the En 2510 B generating sets, it
is possible to install the ASP (optional) automatic
control panel (fig.32) instead of the manual con-
trol panel.
The elements making it up are:
1 ON/OFF switch for the start-up and switch-off
function
2 Display
3 High temperature indicator
4 Minimum oil level indicator
5 Start-up failed indicator
6 Generator running indicator (flashing)
7 Maintenance request indicator
8 Fuel reserve indicator
9 Hour or voltmetric changeover switch button
10 Reset
11 Battery charged indicator
12 Automatic function indicator
13 AUTO/MAN switch for the automatic or man-
ual function
6.8 MANUAL operation
See section 6.1
6.9 AUTOMATIC operation
Turn the AUTO/MAN switch (Fig.32 Ref.13) to
the AUTO position and set the start-up switch
(Fig. 32 Ref. 1) to ON position.
The automatic function indicator (Fig.32 Ref.12)
will light up.
When the voltage at the ends of the 12V DC ter-
minals of the generating set is lower than 11.5
Volts, the generating set will begin the start-up
procedure (similar to that of the manual opera-
tion).
During the operation in automatic mode, the dis-
play (Fig.32 Ref.2) will show the total running
hours of the generating set. Press the hour or
voltmetric changeover switch button (Fig.32
Ref.9) to display the voltage at the ends of the
12V DC terminals, i.e. at the ends of the battery.
When the battery is charged, and anyway after at
least 15 minutes’ running, the battery charged
hours indicator (Fig.32 Ref.11) will light up and
20


Need help? Post your question in this forum.

Forumrules
1

Forum

telair-energy-2510b

Reset search

  • Hello,
    I can not get start on my Telair Energy 2510b. It seems to me that the fuel do not reach the "engine".
    Fuel pump?

    Det ser ikke ut som bensinen suges fra bensintanken. Kan dette være årsaken og evnt.hva må gjøres?
    Jeg tatt service, skiftet olje, skiftet tennplugg og rengjort luftfilter.

    mvh
    Thor, +4795972210
    thor@jemtland.no

    Submitted on 8-7-2022 at 08:48

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Telair Energy 2510b at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Telair Energy 2510b in the language / languages: English as an attachment in your email.

The manual is 4,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info