5 OPERATING INSTRUCTIONS
The generating set is de-
livered without engine oil.
Use oil for multigrade 4-stroke petrol engines,
having SAE viscosity suitable for the operat-
ing climate and in the amount indicated (see
table and detailed indications on the user and
maintenance manual of the engine).
The ENERGY 2510 B series generators consist
of petrol internal combustion engines connected
to an alternator that can produce alternating elec-
trical current. The generating sets are assembled
inside a steel plate casing, insulated and sound-
proofed using special sound absorbing materials.
Fuel is fed to the internal combustion engine via
a pump fitted to the generating set as part of the
standard supply.
5.1 Machine safety
The generating sets come with perfectly sealed
casings, so there is no danger of contact with any
moving or high temperature parts or with live ca-
bles.
The doors open with a lock and key. The keys
must not be left within the reach of children or in-
experienced persons.
The generating sets
must only and exclusively be used with their
doors shut.
Remove any flammable substance (for exam-
ple: petrol, paints, solvents, etc.) from near
the generating sets.
Make sure that any hot parts of the generat-
ing sets are not in contact with any flammable
material.
Never fill up the fuel tank while the engine is
running.
Never touch the generating sets or the wiring
connections with wet hands.
Never replace the fuses or the cut-out
switches with others having higher amper-
age.
Should any electrical part need checking, this
must only be done with the engine turned off
and by specialised personnel.
The generating sets have been built in compli-
ance with the safety standards listed in the EEC
statement of compliance.
6 USING THE GENERATING SET
6.1 Starting up the generating set
The generating sets are provided with an elec-
tronic remote control panel (Fig. 30) which allows
you to perform starting up / turning off operations
and to check their running conditions.
The panel controls are:
1 ON/OFF switch
2 Display unit
3 High temperature indicator
4 Engine minimum oil level indicator
5 Startup failed
6 Generator running (flashing)
7 Engine oil change indicator
8 Fuel warning light
9 Display time changeover switch
10 Reset
Set the startup switch (Fig.30 Ref.1) to its ON
position. The message “WAITwill be displayed
for 8 seconds. After this time, the electronic con-
trol panel will start the first automatic procedure
for starting up the generating set. If the engine
starts up at the end of this phase, the “generator
running” indicator light (Fig.30 Ref.6) will start to
flash.
Should the engine not start up, this automatic
procedure will be repeated up to 4 times.
If, at the end of a complete cycle, the engine has
not yet started up, the “startup failed” indicator
(Fig.30 Ref.5) will light up to signify that the gen-
erating set has failed to start up.
If the “startup failed” indicator (Fig.30 Ref.5) light
only stays lit, you can repeat the procedure sev-
eral times. If the generating set has not started
up after several attempts, contact the manufac-
turer’s After-sales service.
18


Need help? Post your question in this forum.

Forumrules
1

Forum

telair-energy-2510b

Reset search

  • Hello,
    I can not get start on my Telair Energy 2510b. It seems to me that the fuel do not reach the "engine".
    Fuel pump?

    Det ser ikke ut som bensinen suges fra bensintanken. Kan dette være årsaken og evnt.hva må gjøres?
    Jeg tatt service, skiftet olje, skiftet tennplugg og rengjort luftfilter.

    mvh
    Thor, +4795972210
    thor@jemtland.no

    Submitted on 8-7-2022 at 08:48

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Telair Energy 2510b at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Telair Energy 2510b in the language / languages: English as an attachment in your email.

The manual is 4,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info