All electrical connections have to be effected exclusively by authorised and qualified technicians.
Any improper cable connection is forbidden.
Check the integrity of all components and do not install defective or damaged parts. Ask for
replacement.
Check that capacity of the electrical system is sufficient for the maximum rated power shown on the
data rating plate of the machine.
The customer has to protect the electrical feeding of the machine by means of a safety switch
system of 30 mA.
The machine must be installed with an electrical switch with adequate fuses and safety devices.
The machines with electrical input over 16 A, must be connected to a net with impedance
= or < than 0,37 Ω.
Before installation, the manufacturer strongly recommends to control the water supply system and
the electrical connections.
Check the efficiency of the machine’s main drain. Then proceed with the connection of the water
drain hose to the machine. Check again pouring an adequate quantity of water directly into
machine’s drain tray (located under the drip tray).
This equipment must be installed on a flat, level and stable surface. The minimum height of this
surface is 1025 mm
Handle the machine with care.
In case of substitution of the water inlet hose, the used one is not to be reused.
Technical data
Voltage Please refer to the technical data plate on the machine
Wattage Please refer to the technical data plate on the machine
Temperature The machine should not be operated with temperatures under 6°C
and over 36 °C.
Water The machine has to be used with fresh, soft, clean drinking water.
The water hardness being between:
50 to 100 American degrees
7 to 14 German degrees
4 to 8 French degrees
Please install a water filter if necessary.
Water pressure from the mains Maximum water inlet pressure is 6 Bar (0,6 MPa 600 KPa)
Please install a pressure reducing valve if water pressure from the
mains is higher.
The minimum water pressure is 1.5 Bar (0.15MPa-1500 KPa)
Hydraulic connections Water inlet 3/8” gas
Machine ventilation Please make sure that there is an open area of at least 100 mm on
each side and behind the machine to allow adequate ventilation
Boiler capacity 13,50 litres 2 group
20,50 litres 3 groups
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for SV Italia SAB Sophia at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of SV Italia SAB Sophia in the language / languages: English, Italian as an attachment in your email.

The manual is 0,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info