6. Using SunTech CT40 for Heart Rate Measurement
There are two ways to measure heart rate with the SunTech CT40.
BP Heart Rate Measurement
With this method, HR is captured automatically during BP measurement.
SpO2 Heart Rate Measurement
If you have the optional pulse oximetry module on your device, you can measure HR through the SpO2 sensor. See
next section (section 7) for more on use of this option.
The SunTech CT40 uses BP as the default HR source. HR source can be selected using the Advanced Configuration
Application.
7. Using SunTech CT40 for Pulse Oximetry
An optional SpO2 module allows you to measure the oxygen saturation of arterial blood flow and display the reading
on the SunTech CT40. There are two different types of optional SpO2 modules: Masimo® SET® and ChipOx.
General Principle of Operation:
The pulse oximeter directs red and infrared light into a capillary bed and measures the change in light absorption
during the pulsatile cycle. Red and infrared light-emitting diodes (LEDs) in oximetry sensors serve as the light
sources, and a photodiode serves as the photo detector.
Traditional pulse oximetry assumes that all pulsations in the light absorbance signal are caused by oscillations in the
arterial blood volume.
The traditional pulse oximeter calculates the ratio of pulsatile absorbance (AC) to the mean absorbance (DC) at each
of two wavelengths (typically one visible, the other infrared). The oximeter then calculates the ratio of these two
arterial absorbance signals. This value is used to find the saturation SpO2 in a standard table built into the oximeter
software. The values in the table are based upon human blood studies against a laboratory co-oximeter on healthy
adult volunteers in induced hypoxia studies. The resulting value is reported as oxygen saturation level (%).
WARNING: Pulse oximeter probes and sensors are designed for use with specific pulse oximeter devices. Only use
probes and extension/adapter cables that are specified for each SpO2 module.
WARNING: The responsible organization and/or operator must verify the compatibility of the oximeter, oximeter
probe, and extension/adapter cable before use. Otherwise, patient injury can result.
WARNING: Misapplication of a pulse oximeter probe with excessive pressure for prolonged periods can induce
pressure injury.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for SunTech CT40 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of SunTech CT40 in the language / languages: English as an attachment in your email.

The manual is 2,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of SunTech CT40

SunTech CT40 User Manual - German - 49 pages

SunTech CT40 User Manual - Dutch - 52 pages

SunTech CT40 User Manual - French - 50 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info