SummaSign Pro SL D-series Cutters User’s Manual
Operation 2-14
2.4.8 PARITY
The PARITY submenu is used to set or modify the byte format and parity type for
RS-232-C serial communication between the cutter and the host computer.
The default parity setting is bit 8 = 0 (8 data bits, no parity, the 8th bit being a
low bit). The parity can be set to any of the following values:
LCD information Parity setting Remarks
BIT 8 = 0
8 data bits, no parity bit 8 = low (0)
BIT 8 = 1
8 data bits, no parity bit 8 = high (1)
EVEN
7 data bits, 1 parity bit parity bit = even
ODD
7 data bits, 1 parity bit parity bit = odd
The active parity setting is marked with an asterisk (¾) on the LCD.
NOTE
The cutter’s parity setting MUST match the host computer's parity
setting.
2.4.9 RTS/DTR
The RTS/DTR submenu controls the Request To Send (RTS) and Data Terminal
Ready (DTR) signals for the cutter's RS-232-C serial communications interface for
hardware handshaking.
RTS/DTR can be set to TOGGLE (hardware handshaking) or HIGH (software
handshaking).
The RTS/DTR default value is TOGGLE.
The active handshake setting is marked with an asterisk (¾) on the LCD.
56


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Summa SummaSign Pro SL T-series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Summa SummaSign Pro SL T-series in the language / languages: English as an attachment in your email.

The manual is 1,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info