FIRST USE / OPERATION
Please note: never transport the device with a full water tank.
Possible hazards:
too much water from water tank comes into the Main Base.
water can easily come out from the Main Base.
the water tank can fall off from the Main Base and get damaged due to the heavy weight from
the water (and water can leak on to the floor).
1. The Stylies SIRIUS humidifier should be placed first with empty Water Tank (13) in a suitable lo-
cation.
2. When the device is in the desired location: remove the cover (4) at the rear side (magnetic
catch).
3. Hold the water tank (13) firmly by the handle, swivel outwards and pull it upward.
4. Fill Water Tank (13) with fresh water (max. 3.5 l) and screw the Tank Cover (15) back on firmly
and check that it is sealed properly. Place Water Tank on base, and you should hear a bubbling
sound (water collector filling).
5. Plug Power Cable into the power socket.
6. Switch on the device: by touching the «ON/OFF» key on the control panel (1). The display will
show «ON» briefly followed by the current humidity, e.g. «41». Shortly after this, the sound of the
water boiling can be heard and hot steam will be emitted (do not touch!).
Caution: If the red «No Water» warning lights up, the humidifier cannot be switched on. Check
if the water tank is full. If so, it may take a moment to refill the water collector (20) if necessary
(the red light «No Water» then goes out).
7. Never point the steam outlet at walls or furniture, etc. On the display (6), it shows the current
humidity level in the room, e.g. «41 %».
8. The desired air humidity level can be selected by repeatedly touching the «HUMIDIT key
(35–75 % rel.). We recommend 40-60 % rel. air humidity. As soon as the display shows the
current relative air humidity again, the humidity setting is saved and automatically monitored.
Set «CO» for continuous operation without humidity monitoring, but this may cause excess hu-
midity if used too often. The humidifier starts automatically as soon as the humidity is lower
than the setting, and stops when it is higher. During humidification the current air humidity is
displayed.
Note: If «C (continuous operation) is set, the humidifier WILL NOT STOP automatically. To
avoid excessive humidity, use «CO» for a short time only. The device will not switch on if the air
humidity level has been set too low.
9. Set the desired humidifying capacity: by repeatedly touching the «OUTPU key (1= low, 3 =
high).
10. Activate the automatic shutdown time: by repeatedly touching the «TIMER» key. Adjust the
shutdown time in hours (01-12 hours, or «00» to quit timer).
11. Night mode: touch the «NIGHT MODE» key to dim the light. Switch off function by touching any
function key.
12. «No water» warning: this red LED lights up if the water collector is empty or too low. In this
case turn the device off by touching the «ON/OFF» key and fill the tank with fresh water. Then
replace the tank in the base and turn the power on again.
Note: When you remove the tank, some water can flow out of it. To prevent damage, always
turn off the power when the «Low water» warning lights up.
CLEANING PROCEDURE
Switch off the device and unplug the power cable from the socket before all maintenance work
and after each use.
Never submerge the device in water (this can result in short-circuiting). To clean the device,
simply wipe it with a damp cloth and then dry it thoroughly. Descale the humidifier as
appropriate for the hardness of the water, but at least once a week: First remove the water
tank and clean it with a brush. Descale the water collector (20) and the vaporizing plate (21) in
the base with a standard descaler and then rinse it thoroughly. Make sure no water penetrates
inside. So only fill with descaler/water mixture to a height of 2-3 cm.
Reassemble the device completely before use.
Thoroughly rinse out the water tank on a regular basis.
USEFUL INFORMATION:
Information how a vaporizer works
How does the vaporizer work? The vaporizing plate in the interior of the device causes the water
to heat up. The steam is emitted through the opening (2) on top of the device and increases
humidity in the room. Using the hygrostat (see next section), the air humidity in the room can be
monitored and regulated. A vaporizer boosts humidity very quickly. The water is sterile because it
has been boiled.
Hygrostat
The standard-tolerance of an integrated hygrostat is +/- 10%. That means the effective relative
humidity level can deviate accordingly. Please ensure that the hygrostat is never covered
otherwise it won’t function properly.
Tips for water
Do not use water that has been subject to salt-based softening in a descaling system. These
systems replace the calcium with salt, which then settles in the room as a white deposit.
Clean water must always be used to ensure that the air remains hygienic to breathe. The device,
and the water tank in particular, must always be hygienically clean.
TECHNICAL DATA
Dimensions 300 x 160 x 390 mm (width x depth x height)
Weight approx. 2.40 kg
Mains voltage 220-240 V / 50 Hz
Power consumption 350 W
Humidifying capacity up to 350 g/h
Automatic shutoff yes
Water tank capacity 3.5 litres /0.92 US gallons
Suitable for room sizes of 45 m² / 110 m³
EU compliance CE/WEEE/RoHS
Technical changes and errors reserved.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stylies Sirius at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stylies Sirius in the language / languages: English, German, Dutch, French, Italian, Polish, Swedish, Spanish as an attachment in your email.

The manual is 0.9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info