Electric Boilers
SET DHW FLOW & TEMPERATURE
The hot water side of the electrical combination boiler relies on setting the correct ow rate of water going in to
the unit, if the water going in to the unit is too fast then the unit will be unable to cope with the demand and the
water will come out cold. You should aim to set your boiler to approximately the following owrates, you can do
this by restricting the isolation valve tting on the cold water of the inlet during installation.
Rated Boiler Output 7kW 11kW 14.4kW 18kW 21kW 24kW
Recommended Flowrate (LPM) 4 6 7 10 12 13
With the hot water tap open and running the temperature of the hot water outlet can now be set on the boiler by
using the up and down button. The temperature cannot be adjusted without a hot tap being open. Remember
this setting does not guarantee the output, it only sets the maximum possible output, the output temperature will
rely on the ow rate going in to the boiler as above.
COMBINATION BOILERS ONLY
35


Need help? Post your question in this forum.

Forumrules
1

Forum

strom-e-boiler

Reset search

  • After turning off heater, I cannot turn it back on. The Menu button does not work. Submitted on 5-4-2023 at 16:40

    Reply Report abuse
  • the front panel is flashing E5 and I can not change anything Submitted on 13-12-2022 at 13:27

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Strom E-Boiler at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Strom E-Boiler in the language / languages: English as an attachment in your email.

The manual is 3.36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info