813428
8
Zoom out
Zoom in
Previous page
1/44
Next page
8
4.6 Add larger pieces of wood.
Do not use full sized logs at this stage, build up gradually in
size. Too many logs may smother the fire.
Do not load fuel above the log guard or the base of the
baffle, see Diagram 8.
Base of baffle
Log Guard
8
Close the door.
Do not run with the door slightly open except for initial
lighting as this could cause over-firing and damage the
appliance.
Once the fire is established close the Primary Air Controls
and set the thermostat to the desired temperature.
5. Running the Appliance
5.1 Only for use with recommended fuels, see Section 3 for
full details.
— Burning Soild Fuels, see 5.2.
— Burning Wood on a Multi-fuel Grate or when a
Woodburning tray is fitted, see 5.14.
Wood can be burned on the multi-fuel grate, but if wood is
to be used constantly a Woodburning tray should be fitted,
see Section 6.
Burning Soild Fuels
To burn smokeless fuels the cast iron multi-fuel kit supplied
with the product must be fitted.
5.2 Allow the fire to become established before adding the solid
fuel, see Section 4.
5.3 Open the Primary Air Control fully to establish a glowing
bed before adding new fuel.
5.4 De-ash the grate before re-fuelling (see User Instructions,
Section 8).
5.5 Add the correct amount of fuel, see Section 3.
5.6 Close the doors immediately after refuelling.
Burn new fuel at a high temperature for a few minutes before
adjusting the Primary Air Control to the desired setting.
User Instructions
Refuel little and often for clean, efficient burning.
Manually operate the following air controls using a
gloved hand or the tool provided.
9Airwash: Closed
Primary Air: Closed
Thermostatic
Control: Adjust
5.7 Close the Primary and Airwash Controls.
5.8 Control the temperature and hot water output using the
Thermostatic Control.
THERMOSTAT
This appliance is designed to be controlled by the
thermostat which regulates the rate fuel is burnt
and the amount of heat produced to hot water.
A trial and error approach will establish settings to
suit personal preference.
5.9 The thermostat operates by controlling combustion air
entering the boiler. The higher the thermostat setting the
hotter the temperature of the water leaving the boiler. The
lower the setting the lower the temperature of the water
leaving the boiler.
NOTE IF THE THERMOSTAT IS SET TO
MAXIMUM THE WATER LEAVING THE BOILER
WILL BE APPROXIMATELY 85˚C.
Setting Indicator
-
+
10
Control Knob
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stovax View 7 Inset High Output Boiler Inset at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stovax View 7 Inset High Output Boiler Inset in the language / languages: English as an attachment in your email.

The manual is 4.77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info