720798
7
Zoom out
Zoom in
Previous page
1/194
Next page
7
GB
3 Button
Used to change temperature units from Fahrenheit to
Celsius.
When setting emissivity (
), high alarm value (HAL),
or low alarm value (LAL), press this button to
decrease the value to be set.
4 MODE Button
Each time you pull the trigger (for > 1 sec) to take
measurements, the thermometer records the maximum
(MAX), minimum (MIN), the differential (DIF) between the
maximum and the minimum, and the average (AVG) of
all readings taken during this pull. These data are stored
in memory and can be recalled with the MODE button
until you pull the trigger (> 1 sec) once more. When you
pull the trigger (> 1 sec) once more, all these data will
be erased from memory and the thermometer will start
a new recording.
When you pull and hold the trigger, the reading on
the main display will update every second with the
temperature of the target surface, and when you release
the trigger, the last reading is locked until you take new
measurement or the thermometer turns off automatically.
You can press the MODE button to display the maximum
(MAX), average (AVG), minimum (MIN), difference
(DIF), low alarm value (LAL) and high alarm value
(HAL) sequentially on the bottom display. The process is
illustrated in Figure A.
NOTE:
To read value correctly, please observe the bottom display
carefully to see whether the negative sign „-” and the
decimal point appear.
After you disconnect the battery from the thermometer for
a while, all the settings will be restored to default values
and all the recorded measurement data will be erased
from memory.
How to Set the Thermometer
Setting the High Alarm and Low Alarm
1. After the thermometer has been turned on, press and hold
down the MODE button until the symbol ashes, then
release the button.
2. Press the MODE button until LAL appears and ashes,
now the present low alarm value is being shown on the
bottom display.
3. Press the
button to decrease or the button to
increase the low alarm value.
NOTE: Press and hold down the
or button for
fast adjustment.
4. After setting the low alarm value, press the MODE button.
HAL ashes and the high alarm value is shown on the
bottom display. Use the same method of Step 3 to adjust the
high alarm value.
5. If the temperature of target surface reaches or is lower
than the low alarm value,
icon will appear and
ash and the built-in buzzer will beep and the LCD will
momentarily turn blue when you press and hold the trigger.
If the temperature of target surface reaches or is higher than
the high alarm value, icon will appear and ash and
the buzzer will beep and the LCD will momentarily turn red
when you press and hold the trigger.
6. At any time, you can press and hold down the MODE button
to exit setting mode.
NOTE:
Alarm accuracy is ± 1°C (or ± 2°F).
The low and high alarm values can be set only within the
thermometer’s measurement range.
The high alarm value must be higher than the low
alarm value.
Emissivity/ Setting Emissivity
Emissivity describes the energy-emitting characteristics of
materials. Most (90% of typical applications) organic materials
or non-shiny surfaces have an emissivity of 0.95 in the
default setting. Inaccurate readings will result from measuring
shiny or polished metal surfaces. To compensate, cover
the surface to be measured with masking tape or at paint.
Allow the tape or paint to reach the same temperature as the
surface it is covering. Then measure the temperature of the
covered surface.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stanley FMHT0-77422 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stanley FMHT0-77422 in the language / languages: All languages as an attachment in your email.

The manual is 14,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info