2.11 CHIMNEY CONNECTION / CONNECTING PIECES
The Nova E H2O is connected to the chimney with the connecting pieces
made from steel sheet at least 2 mm thick. These connecting pieces
must satisfy the requirements specified in DIN 1298 and DIN EN 1856-
2, and must be connected to the chimney / flue gas system in accord-
ance with the requirements specified in DIN 18160 or the country-specific
regulations. It must be ensured that the flue gas pipe takes the shortest
possible route upwards towards the chimney. The number of bends in the
flue gas pipe should be kept to a minimum. In addition, the flue gas pipe
must be connected to the chimney with a bricked-in wall lining and sealed.
If necessary, the flue gas pipe must be fastened with clamps to ensure
adequate fixation. The connecting pieces must be sealed if necessary! If the
flue gas pipe is routed through components with flammable building materi-
als, the flue gas pipe must be insulated as specified in the regulations. The
connecting line must always be mounted in such a manner that it is possible
to clean the connecting line at any time.This must be ensured through a suf-
ficient number of cleaning openings. A gauge connection must be installed
so that it is accessible for determination of the negative chimney pressure
in the connecting line.
2.12 INSTALLATION OF ROTATING DISC / AIR
ADJUSTMENT LEVER / SERVOMOTOR FOR
S-THERMATIK
After delivery, it may be necessary to mount the rotating disc through the
combustion chamber in the floor area of the tiled stove (e.g. device design
with S-Thermatik). Installation is not executed in the factory because the
star adapter (frictional connection between servomotor and rotating disc),
as well as the servomotor for the S-Thermatik project downwards out of
the device. These components would be damaged through transport and
installation.
For installation, removal of the front combustion chamber chamotte (cha-
motte brick no.: 7 and 8 Fig. 4) and of the combustion chamber floor are
necessary. Installation of the air mechanism must be executed as shown
in Fig. 3a. The air adjustment lever must be in the „closed“ position (air
adjustment lever at the left stop), so that the primary ventilation damper
can be inserted. After installation, the function of the air controller must be
checked before installation of the combustion chamber floor. For this, the
inspection opening in the front chamfer of the combustion chamber bowl
must be opened. Through this opening, it must be possible to determine the
opening of the primary ventilation damper when the air adjustment lever
is in the right position. If the air adjustment lever is turned to the left, the
primary ventilation damper must close.
Star adapter
for frictional
connection
Rotating disc
VA slide plate
Bores for holder of the servomotor
(only for S-Thermatik). The support
of the servomotor is installed through
the large cut-out in the base plate.
Base plate
The bore of the articulated
arm must be fitted on the
bolt of the air adjustment
lever.
Fig. 4
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Spartherm Nova E H2O at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Spartherm Nova E H2O in the language / languages: English as an attachment in your email.

The manual is 3.39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Spartherm Nova E H2O

Spartherm Nova E H2O User Manual - German - 28 pages

Spartherm Nova E H2O User Manual - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info