12. twin operation
9. Put both operators into operation successively, see
chapter "9. Initial operation," "10. Connections
and special functions of the motor carriage" and
"11. Connections and special functions of the
wall control unit."
10. Programme the handheld transmitters for the
respective operators, see chapter "10.4 Explanation
of the radio channels" and "10.5 Programming
the transmitter."
INFORMATION
Only one handheld transmitter button
can be assigned per function. Undesired
malfunctions could otherwise occur.
12.4 Partial opening
One partial opening can be programmed for each of
the two operators (master and slave). Programming or
deletion is performed as for the standard equipment,
see chapter "10.17 Setting partial opening” and
"11.6 Deleting partial opening."
Example:
Master on radio channel CH 2 (partial opening) on
handheld transmitter button 3. For the slave, on radio
channel CH 2 (partial opening) on handheld transmitter
button 4.
Corded
The input COM and signal on the wall control unit can
be used for this purpose. DIP switch 4 on the wall control
unit must be set to "ON."
The input is then no longer available for connection of
a photocell.
Mode of operation
If button 2 (partial opening) is activated, the master
receives the partial opening command. See also chapter
"10.17 Setting partial opening."
12.5 Defined opening and closing
The functions defined opening and closing of the
operators (master and slave) can only be configured via
the CH 3 and CH 4 radio channels. These settings are
not available when corded or via the Conex accessory
part.
12.6 Door status display
During door movement and if the door is not closed, the
relay (MUFU) trips. DIP switch 2 must be "ON." The relay
remains activated until both operators (master and slave)
are again at the door CLOSE end position.
12.7 Lighting for twin operation
The lighting can be switched on and off for the selected
operator via the respective handheld transmitter.
This also applies for the connected supplemental lighting,
see also Chapter "10.16 Setting the lighting function."
12.8 Photocell
Optionally, a photocell can be connected. The photocell
must be configured in such a way that it can be aligned
to cover two doors. If the photocell is interrupted, the
operator of the moving door reverses. See also chapter
"11.7 Photocell and frame photocell."
INFORMATION
If a photocell is retrotted on a pro-
grammed system, the control unit must
be reset, see Chapter "10.13 Performing
a reset."
12.9 External button
With the Conex additional circuit board, both operators
(master and slave) can be operated in pulse sequence
mode. Fit the Conex as described in the separate
instructions. Set DIP switch 1 on the wall control unit
to "ON."
Mode of operation
Button 1 - master
Button 2 - slave
12.10 Reset
The slave becomes the master again when a factory
reset is carried out. The operator must be configured as
the slave again via SOMlink and a WiFi-enabled device,
see chapter "12.3 Selecting and configuring master
and slave."
64


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sommer S 9080 pro at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sommer S 9080 pro in the language / languages: English as an attachment in your email.

The manual is 10,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sommer S 9080 pro

Sommer S 9080 pro User Manual - German - 88 pages

Sommer S 9080 pro User Manual - Dutch - 88 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info