Provisioning Guide M700, M300 Settings and Configuration
Server Settings
Server Settings
Setting Value(s) Description
NOTE: Up to 10 servers with idx 1 to 10. Example: user_host idx="1"
srv_sip_use_one_tcp_
conn_per_ext
idx=1-10
o / on Specifies whether to use one
TCP connection per
SIP extension or not.
Default Value: o
srv_sip_signal_tcp_port
idx=1-10
o / on Specifies whether to signal TCP source port or not.
Default Value: on
srv_sip_server_alias
idx=1-10
e.g. snom sip server Specifies the name of the sip server.
Default Value: <empty>
srv_sip_show_ext_
name_in_hs
idx=1-10
o / on Specifies whether the e
xtension is shown on the
handset idle screen or not.
Default Value: on
srv_sip_enable_blind_
transfer
idx=1-10
o / on Specifies whether blind tr
ansfer is enabled or not
Default Value: on
network_vlan_
synchronization
o / on When the VLAN ID in a multicell system changes,
this setting determines whether the new VLAN ID
is sync'd to the other bases or not.
Default Value: on
srv_srtp_auth
idx=1-10
o / on Determines whether SRTP Authentication is used
or not. This setting has to be enabled when user_
srtp is set to on. Likewise this has to be turned o
when user_srtp is o.
Default Value: o
srv_sip_rtp_base_equal
idx=1-10
disabled / enabled Enables/disables R
TP from own base station.
Default Value: disabled
srv_sip_ua_data_
server_nat_adaption
idx=1-10
disabled / enabled Enables/disables NA
T adaption.
Default Value: enabled.
NOTE:
user_dtmf_info
idx=1-10
sip_inf
o_only = SIP info
o = RTP Events (RFC2833)
on = SIP info and RTP
Events (RFC2833 )
This setting changes depending on whether DTMF
events are signaled via SIP INFO messages or via
RTP events or both.
Default Value: o
srv_dtmf_payload_type
idx=1-10
0-127 Set up the payload type for out-of-band DTMF here.
Default Value: 101
srv_sip_transport
idx=1-10
udp / tcp / tls Specifies the transport protocol used for SIP
messages.
Default Value: udp
timer_support
idx=1-10
o / on Define whether sip-stack should support the use of
timer
s. Includes adding headers "Session-Expires"
and "Min-SE".
Default Value: on
Enabled: When the base station receives a SIP response to a REGISTER request with a “Via” header
that includes the “received” parameter (e.g.: Via: SIP/2.0/UDP 10.1.1.1:4540;received=68.44.20.1), it will
adapt its contact information to the IP address from the "received" parameter. The base station will
then send another REGISTER request with the updated contact information.
Disabled: The base station will ignore the "received" parameter.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Snom M300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Snom M300 in the language / languages: English as an attachment in your email.

The manual is 0,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Snom M300

Snom M300 User Manual - English - 44 pages

Snom M300 User Manual - English - 84 pages

Snom M300 User Manual - English - 58 pages

Snom M300 User Manual - German - 82 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info