Admin and Installation Guide M700, M300 Description of Settings
Setting Description
Attended transfer behavior Depending on whether the PBX requires the second call to be active (i.e., not
on hold) before the REFER is sent, this setting denes whether pressing the
"Transfer" function key on a handset will put the second call on hold.
Setting "Hold 2nd Call": Pressing the transfer key puts the second call on hold
before REFER is sent.
Setting "Do Not Hold 2nd Call": Pressing the transfer key results in sending of
REFER without rst putting the second call on hold.
Default: Hold 2nd Call
Use own codec priority This setting species whether the incoming call's codec priority (setting:
disabled) or the system's own codec priority (setting: enabled) will be used
for the call.
Default: Disabled
DTMF signaling This setting species how the decimal digits (and ‘*’ and ‘#’) are converted
into sounds that share similar characteristics with voice to easily traverse
networks designed for voice.
SIP INFO: Carries application-level data along SIP signalling path (for
example: DTMF digits generated during SIP session or DTMF tones via data
packets in the same internet layer as the voice stream, etc.).
RFC 2833: DTMF handling for gateways, end systems, and RTP trunks (e.g.:
Sending DTMF tones via data packets in dierent internet layer as the voice
stream).
Both: Enables SIP INFO and RFC 2833 modes.
Default: RFC 2833
DTMF payload type This setting allows the user to specify a value for the DTMF payload type /
telephone event (RFC2833).
Default value: 101
Remote Caller ID Source
Priority
SIP information eld used for Caller ID source. Options:
PAI - FROM
FROM
ALERT_INFO - PAI - FROM
Enable blind transfer This setting species whether blind transfer of calls is allowed (enabled) or
not.
Default: Enabled
Codec priority This setting species the codec priority for audio compression and
transmission. After changing the order of priority with the Up/Down buttons,
click on Reset codes.
NOTE: In a multicell setup, you must also go to the multicell page and click on
Reboot chain in order to update the handsets in the multicell installation.
Options: G.722; G.711A-law, �-law; G.726
NOTE:
With G.722 in the list, the codec negotiation algorithm is active. This causes
the handset setup time to be slightly slower than when G.722 is removed
from the list.
With G.722 as rst priority, the number of simultaneous calls per base station
will be reduced from 10 (8) to 4 calls.
RTP packet size This setting species the packet size oered as preferred RTP packet size
during RTP packet size negotiation.
Default value: 20 ms
63


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Snom M300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Snom M300 in the language / languages: English as an attachment in your email.

The manual is 2.57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Snom M300

Snom M300 User Manual - English - 44 pages

Snom M300 User Manual - English - 38 pages

Snom M300 User Manual - English - 58 pages

Snom M300 User Manual - German - 82 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info