CLEANING AND MAINTENANCE - 13191477A327/B
e
9. Clean and dry any residual water inside the
oven cavity.
Reservoir draining
10.Open the door
11. Place a jug or container on the open door.
12.Remove the loading wand from its holder.
13.Press the START button to start draining
the water into the jug (or container).
14.Wait for the end of the drain flow.
When complete, the display will indicate that
the residual water removal process is complete.
15.Touch the CONFIRM button.
16. Shake the loading wand in order to remove
any remaining water.
17.Place the loading wand back in its holder.
18.Remove the jug (or container).
19. Drain the water from the jug.
20.Close the door.
Sanitization
Sanitization with steam allows to remove the last
residues of descaling from the hydraulic circuit.
1. set a 70% combined steam function lasting
at least half an hour.
2. Fill the jug with clean water.
3. Open the appliance door.
4. Rest the jug on the open door.
5. Remove the loading wand from its holder.
6. Place the end of the tube at the bottom of
the jug (or container).
7. Press the start button to start filling the
appliance reservoir with water.
8. When finished, shake the loading wand to
remove any water residue.
9. Place the loading wand back in its holder.
10.Remove the jug (or container).
11.Close the door.
12. Touch the START button to start the
selected steam function.
13.Wait for the function to be executed until the
end.
14. At the end of the function, drain the reservoir
as described above.
15.Wait for the end of the drain flow.
16.Drain the water from the jug.
17.Open the door.
18.Wipe off any spillage of water in the oven
cavity with a cloth or sponge.
19.Close the door.
Reservoir calibration
Over time, the quantities of water in the reservoir
may not be read correctly by the appliance
sensor. In this case, the functionality of the
appliance sensor can be restored to an optimal
condition.
Preliminary operations
1. Touch the OTHER FUNCTIONS
button on the "main menu" (in the main area
).
2. Touch the sub-menu button (located in
the lower area ).
3. Touch the RESERVOIR CALIBRATION
button (positioned in the lower area
).
Empty reservoir calibration
1. Open the appliance door.
It is recommended to carry out the
cleaning process of the reservoir and
the water circuit a couple of times.
You can also use a cleaning solution
instead of water. In this case it is
advisable to carry out at least a couple
of water rinses afterwards, following the
instructions in this chapter.
Take care: wait for the oven cavity to
cool down.
This function allows you to calibrate the
correct reading of the quantity of water
(or other liquid) inside the reservoir.
59


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Smeg SO4104 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Smeg SO4104 in the language / languages: English as an attachment in your email.

The manual is 2.7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info