791163
61
Zoom out
Zoom in
Previous page
1/66
Next page
INSTALLATION - 13391477A327/B
e
12.Touch the CONFIRM button to end the
reservoir calibration procedure.
The display suggests to drain the water from the
reservoir. You can either use the water for steam
cooking or proceed as described in the chapter
for Reservoir draining.
Extraordinary maintenance
Seal maintenance tips
The seal should be soft and elastic.
To keep the seal clean, use a non-abrasive
sponge and wash with lukewarm water.
INSTALLATION
Electrical connection
General information
Check the mains characteristics against the data
indicated on the plate.
The identification plate bearing the technical
data, serial number and brand name is visibly
positioned on the appliance.
Do not remove this plate for any reason.
The appliance must be connected to ground
using a wire that is at least 20 mm longer than
the other wires.
The appliance can work in the following modes:
220-240 V~
3 x 1.5 mm² three-core cable.
Fixed connection
Fit the power line with an all-pole circuit breaker
with a contact separation distance sufficient to
provide complete disconnection in category III
overvoltage conditions, pursuant to installation
regulations.
For the Australian/New Zealand market:
The circuit breaker incorporated in the fixed
connection must comply with AS/NZS 3000.
Connection with plug and socket
Make sure that the plug and socket are of the
same type.
Avoid using adapters, gang sockets or shunts as
these could cause overheating and a risk of
burns.
Cable replacement
1. Unscrew the rear casing screws and remove
the casing to access the terminal board.
2. Replace the cable.
3. Make sure that the cables (for the oven or
any hob) follow the best route in order to
avoid any contact with the appliance.
See General safety instructions.
The values indicated above refer to the
cross section of the internal lead.
The aforementioned power cables are
sized taking into account the
coincidence factor (in compliance with
standard EN 60335-2-6).
Power voltage
Danger of electrocution
Disconnect the mains power supply.
61


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Smeg SO4104 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Smeg SO4104 in the language / languages: English as an attachment in your email.

The manual is 2.7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info