Operational procedures
37
850-164692 / Rev.B
convenient range for the echogram, the distance between the
lines will give a good indication of the frequency causing the
noise.
Noise speed tests should be performed after all the frequencies
have been calibrated. All the frequencies can be measured
simultaneously. Thus, you should install all transceivers in
ER60.
Procedure
Observe the following procedure.
Initial set-up
1 On the Install menu, open the Transceiver Installation
dialogue. Ensure that all the transceivers are installed.
2 On the Operation menu, select Normal to open the
Normal Operation dialogue. Set the following
parameters:
a Passive mode
b Maximum transmit power
c Same pulse duration as used during the calibration
d 0.0 m transducer depth
3 From the Operation menu, open the Ping Control
dialogue. Set the following parameters:
a Maximum ping rate
b Switch off all external triggering
4 Right-click in the Echogram view, and select Echogram
on the shortcut menu to open the Echogram dialogue. Set
the following parameters:
a Surface reference
b Sv backscatter
5 Right-click in the Colour Scale view, and select Colour
Scale on the shortcut menu to open the Colour Scale
dialogue. Set the following parameters:
a Minimum level -100 dB (chosen to give a reasonable
ping rate)
b Maximum level -64 dB
6 Right-click in the Echogram view, and select Range on
the shortcut menu to open the Surface Range dialogue.
Set the following parameters:
a Start relative surface: 0 m
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Simrad ER60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Simrad ER60 in the language / languages: English as an attachment in your email.

The manual is 3,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info