555849
2
Zoom out
Zoom in
Previous page
1/8
Next page
CE2N2462E / 09.12.1998 Siemens Building Technologies
2/8 Landis & Staefa Division
Auto
Automatic operation normal / standby
Automatic changeover between normal temperature and standby according to
the 24-hour or weekly program, ECO automatic energy saver, d.h.w. heating
Auto
Automatic operation normal / reduced
Automatic changeover between normal and reduced temperature according to
the 24-hour or weekly program, ECO automatic energy saver, d.h.w. heating
Setback mode
Continuous heating to the reduced temperature, with ECO automatic energy
saver, d.h.w. heating
Normal mode
Continuous heating to the normal temperature, no ECO automatic energy
saver, d.h.w. heating
Standby
Manual operation
Control switched off, d.h.w. charging pump and hating circuit pump running
Automatic d.h.w. heating only
Heating control on standby
Note: d.h.w. heating is provided only by the RVP210
Type of unit Type
reference
Heating controller without time switch
RVP200.0
Heating controller with analog 24-hour time switch
RVP200.1
Heating controller without time switch, with d.h.w. heating
RVP210.0
Heating controller with analog 24-hour time switch, with d.h.w. heating
RVP210.1
Analog 24-hour time switch
AUZ3.1
Analog weekly time switch
AUZ3.7
Digital weekly time switch
AUD3
Flow, boiler and d.h.w. temperature: all detectors with LG-Ni 1000
at 0 °C, such as:
Clamp-on temperature detector QAD22
Immersion temperature detector QAE22... or QAP21.3
Outside temperature: (controller automatically identifies the type of detector used):
Outside detector QAC22 (Ni measuring element)
Outside detector QAC32 (NTC measuring element)
Room temperature; there are two types of room units available:
Room unit QAW70 with room detector,
time switch, setpoint adjustment and room
temperature readjustment (setting knob)
Room unit QAW50 with room detector,
room temperature readjustment
(setting knob)
Operating modes
Type summary
Equipment
combinations
Suitable detectors and
room units
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens RVP210 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens RVP210 in the language / languages: English as an attachment in your email.

The manual is 0,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info