Siemens Building Technologies Product-Data Sheet Radio signal unit REV... CE1N2255en
Landis & Staefa Division 16.10..2000
Setpoint for frost protection
Adjustable
Factory setting
3 / 5 / 10 °C
5 °C
Resolutions of settings and display
Setpoints
Switching times
Measurement of actual value
Display of actual value
Display of time of day
0.2 °C
10 min
0.1 °C
0.2 °C
1 min
SRD band
Transmitting frequency REV22RF
Max. transmitting power
Max. data throughput
Modulation
Frequency stability
Address range
(factory setting)
868.7 to 869.2 MHz
868.95 MHz
< 10 mW / typically 4 mW
19,200 symbols/s=38,400 Bit/s
binary frequency changeover BFSK
< ±20 ppm (±17 kHz)
16 Bit (0...65535)
Operation
Climatic conditions
Temperature
Humidity
to IEC 721-3-3
class 3K3
0...+35 °C
<95 % r. h.
Transport
Climatic conditions
Temperature
Humidity
Mechanical conditions
to IEC 721-3-2
class 2K3
25...+70 °C
<95 % r. h.
class 2M2
Storage
Climatic conditions
Temperature
Humidity
to IEC 721-3-1
class 1K3
25...+70 °C
<95 % r. h.
conformity
EMC directives
R&TTE directives
89/336/EEC
99/5/EEC
Product norm
Radio equipment ETSI-ETS 300 683
Electromagnetic compatibility
Immunity
Emissions
Radio equipment
EN 50082-1
EN 50081-1
ETS 300 220
Approval
In the following countries
0885
!
all EEC countries,
Norway, Iceland and Switzerland
C-Tick
N474
Devices of safety class
Degree of pollution
III to EN 60 730-1
normal
Weight 0.24 kg
Colour signal-white RAL 9003
General data transmitter
Environmental
conditions controller /
transmitter
Norms and standards
controller / transmitter
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens REV22RF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens REV22RF in the language / languages: English as an attachment in your email.

The manual is 0,35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Siemens REV22RF

Siemens REV22RF User Manual - German - 2 pages

Siemens REV22RF User Manual - Dutch - 2 pages

Siemens REV22RF User Manual - French - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info