3. Meridian as a dive computer
SCUBAPRO MERIDIAN
3. Meridian as a dive computer
pressure  oxygen,  and can  vary in  terms
of  the  exact  level  of  partial  pressure  they 
happen  at.  It  is  commonly  accepted  that 
partial pressures up to 1.4 bar are tolerable, 
and  several  training  agencies  advocate 
maximum  oxygen  partial  pressures  up  to 
1.6 bar.
Long  exposure  effects  to oxygen  partial 
pressures over 0.5 bar due to repeated and/
or long dives. These can affect the central 
nervous system, cause damage to lungs or 
to other vital organs. Long exposures can 
be divided to more severe Central Nervous 
System  effects  and  less  dangerous  long 
term Pulmonary Toxicity effects.
Meridian  treats  high ppO
2
and  long 
exposure effects in the following ways: 
Against  sudden  effects:  Meridian  has 
an  MOD  alarm  set  for  a  user-defined 
ppO
2
max.  As  you  enter the  oxygen
concentration for the dive, Meridian shows 
you the corresponding MOD for the defined 
ppO
2
max.  The  default  value  of  ppO
2
max 
from  the  factory  is  1.4bar.  This  can be 
adjusted  to  your  preference  between  1.0 
and  1.6bar.  It  can  also  be  turned  OFF.
Please  refer  to  chapter  3.2 Gas settings
for more information on how to change this 
setting.
Against  long  exposure  effects:  Meridian 
“tracks”  the  exposure  by  means  of the 
CNS  O
2
clock.  At  levels  of  100%  and 
higher there is risk of long exposure effects, 
and consequently Meridian will activate an 
alarm when this level of CNS O
2
 is reached. 
Meridian can also warn you when the CNS 
O
2
level  reaches  75%  (see  section CNS 
alarm).  Note that  the  CNS  O
2
clock is 
independent  of  the  value  of  ppO
2
max  set 
by the user.
The  CNS  O
2
clock  increases  when  the 
oxygen  partial  pressure  is  higher  than 
0.5bar,  and  decreases  when  the  oxygen 
partial  pressure  is  lower  than  0.5bar. 
Hence,  while  on  the  surface  breathing  air 
you will always be decreasing the CNS O
2
clock. During the dive, the depth at which 
0.5bar  is  reached  for  various  mixes  is  as 
follows:
Air: 13 m / 43 ft
32% 6 m/20 ft
36%: 4m/13ft
F
NOTE:
the O
2
concentration of Gas d can
only be set to a value higher than the
O
2
concentration for Gas 1.
O
2
concentration setting shown “- -“
means that gas is disabled.
Meridian requires that the MODs of
Gas 1 and Gas d be at least 3m/10ft
apart.
Setting the ppO
2
max value to OFF
applies to Gas 1 only. Gas d is
always limited to a maximum value of
ppO2max of 1.6bar.
For oxygen concentrations of 80%
and higher, the ppO
2
max is fixed at
1.6 bar and cannot be changed.
The MOD for Gas d is the switch depth
for that gas. This is what Meridian
uses for its calculation, warnings and
suggested switch point.
When diving with more than one gas
mixture, the Nitrox reset time function
(described in section 2.3.5) has the
following effect:
Gas 1 is set to 21%
Gas d is set to OFF.
3.10.1 Diving with two gas mixtures
Meridian  is  equipped with  the  ZH-L8 
ADT MB  PMG  algorithm.  PMG stands for 
Predictive  Multi  Gas,  meaning  that  when 
you  program  more  than  one  gas  mixture, 
Meridian  will  predict  the  switch  to  the 
higher  oxygen  concentration gas  at  the 
depth  that  you  specified  and  alert  you  at 
all  times  with  a  decompression  schedule 
comprehensive  of  both  gas  mixtures  that 
you  programmed.  In  other  words,  you 
get  full  credit  at  any  point  during  the  dive 
for  all  the  extra  gas  that  you  are  carrying 
with  you.  At  the  same  time  Meridian  can 
also  show  you  what  the  decompression 
schedule  would  be if  you  were  to  finish 
the  dive  using  only  the  gas  mixture  that 
you  are  currently  breathing  from,  so  that 
you  can  be prepared  in  the  event  that 
38


Need help? Post your question in this forum.

Forumrules
1

Forum

scubapro-meridian

Reset search

  • Hi. What is error message E37 on the Meridian. Just did a dive and computer would not go into dive mode. When I came out it said E 37 Submitted on 27-4-2024 at 12:45

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scubapro MERIDIAN at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scubapro MERIDIAN in the language / languages: English as an attachment in your email.

The manual is 2,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Scubapro MERIDIAN

Scubapro MERIDIAN User Manual - German - 58 pages

Scubapro MERIDIAN User Manual - Dutch - 58 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info