782522
19
Zoom out
Zoom in
Previous page
1/112
Next page
english 15
residue. When the power plug is pulled, open the protec-
tion box cover and remove any saw dust obstructions.
m Electrical connection
The installed electric motor is completely wired ready for
operation.
The customer’s connection to the power supply system, and
any extension cables that may be used, must conform with
local regulations.
MOTOR BRAKING UNIT
The scheppach Tisa 3.0 circular saw bench is fitted with an
automatic motor braking unit which becomes effective as
soon as the driving motor is switched off.
IMPORTANT REMARK:
The electric motor is designed for the S 6 / 40 % operating
mode.
Therefore, the motor is automatically switched off in the event
of an overload. The motor can be switched on again after a
cooling down period that can vary.
Defective electrical connection cables
Electrical connection cables often suffer insulation dam-
age. Possible causes are:
Pinch points when connection cables are run through
window or door gaps.
Kinks resulting from incorrect attachment or laying of
the connection cable.
Cuts resulting from running over the connecting cable.
Insulation damage resulting from forcefully pulling out
of the wall socket.
Cracks through aging of insulation.
Such defective electrical connection cables must not be used
as the insulation damage makes them extremely hazardous.
Check electrical connection cables regularly for damage.
Make sure the cable is disconnected from the mains when
checking.
Electrical connection cables must comply with the regula-
tions applicable in your country.
SINGLE-PHASE MOTOR
The mains voltage must coincide with the voltage spec-
ified on the motor’s rating plate.
Extension cables up to a length of 25 m must have a
cross-section of 1.5 mm2, and beyond 25 m at least
2.5 mm2.
The connection to the mains must be protected with a
16 A slow-acting fuse.
THREE-PHASE MOTOR
The mains voltage must coincide with the voltage spec-
ified on the motor’s rating plate.
The mains connection and the extension cable must
have 5 conductors: 3 phase conductors + 1 neutral
conductor + 1 earth conductor.
The extension cable must have a minimum cable
cross-section of 1.5 mm2.
The connection to the mains must be protected with a
16 A slow-acting fuse.
The rotating direction must be checked when the
machine is connected to the mains or re-sited. If
necessary, the polarity will have to be changed over
(wall socket).
Only a qualified electrician is permitted to connect the ma-
chine and complete repairs on its electrical equipment.
In the event of enquiries please specify the following data:
Motor manufacturer
Type of current of the motor
Data recorded on the machine’s rating plate
Data recorded on the switchs rating plate
If a motor has to be returned, it must always be dispatched
with the complete driving unit and switch.
Special Accessories
Cross cutting jig
Item no. 5100 2100
Slide carriage
Item no. 7951 0000
Plate cutting device
Item no. 7961 0000
Slide handles
Item no. 7963 1000
Automatic starter
Item no. 7910 4010 type ALV 2
Item no. 7910 4020 type ALV 10
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scheppach Tisa 3.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scheppach Tisa 3.0 in the language / languages: All languages as an attachment in your email.

The manual is 2.65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info