12. Electrical Connection
m WARNING! Electric shock! There is a risk of
an injury caused by electric shock!
Defective cable or plug may cause electric shock.
Avoid body contact with earth parts to protect your-
self from electric shocks.
m Operation is only allowed with a safety switch
against stray current (RCD max. stray current of
30mA).
Insert the plug of the electrical cable in a socket of
suitable shape, voltage and frequency complying
with current regulations.
Do not pull the service cable to pull the plug out of
socket.
The electric motor is connected in a ready-to-
operate state. The connection corresponds to
the relevant VDE and DIN regulations.
The mains connection at the customer’s work
place and the extension cable used must cor-
respond to these regulations.
The product meets the requirements of EN
61000-3-11 and is subject to special connection
conditions. This means that use of the product
at any freely selectable connection point is not
allowed.
Given unfavorable conditions in the power sup-
ply the product can cause the voltage to uctu-
ate temporarily.
The product is intended solely for use at con-
nection points that
a) do not exceed a maximum permitted supply
impedance „Z“, or
b) have a continuous current-carrying capacity
of the mains of at least 100 A per phase.
As the user, you are required to ensure, in con-
sultation with your electric power company if
necessary, that the connection point at which
you wish to operate the product meets one of
the two requirements, a) or b), named above.
Important information
In the event of an overloading the motor will switch
itself off. After a cool-down period (time varies) the
motor can be switched back on again.
Faulty electrical connecting leads
Insulation damage often occurs at electrical con-
necting leads.
Causes include:
Pressure marks caused when connecting leads
are run through windows or the cracks of doors.
Folds caused by the improper attachment of run-
ning of the connecting leads.
Cutsresulting from the crossing of the connect-
ing lead.
Insulation damages caused by the ripping out of
the connecting lead from the wall socket.
Cracks due to the ageing of the insulation.
Faulty electrical connecting leads such as these
may not be used and are highly dangerous due to
the insulation damage.
Check electrical connecting leads regularly for
damage. Ensure that the connecting lead is not at-
tached to the mains supply when you are checking
it.
Electrical connecting leads must correspond to the
relevant VDE and DIN regulations. Only use con-
necting leads with the code H05VV-F.
The type designation must be printed on the con-
necting lead by regulation.
AC motor
The supply voltage must be 230 volt ~ / 50 Hz.
Extension leads up to 25 m in length must have
a cross-section of 1.5 mm², > 25 m length / 2,5
mm².
Connections and repairs of electrical equipment
may only be performed by a qualied electrician.
Please give the following information if you have
any enquiries:
Kind of current
Machine type label data
Data on the main label
13. Disposal and recycling
The equipment is supplied in packaging to prevent it
from being damaged in transit. The raw materials in this
packaging can be reused or recycled. The equipment
and its accessories are made of various types of mate-
rial, such as metal and plastic. Never place defective
equipment in your household refuse. The equipment
should be taken to a suitable collection center for proper
disposal. If you do not know the whereabouts of such a
collection point, you should ask in your local council of
ces.
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scheppach HMS850 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scheppach HMS850 in the language / languages: English, German, Danish, French, Italian, Polish as an attachment in your email.

The manual is 6,85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info