782262
36
Zoom out
Zoom in
Previous page
1/48
Next page
Pallet truck................................................................................................................................... Art.Nr.
Saw blade guard ......................................................................................................................... Art.Nr.
Stop ruler ..................................................................................................................................... Art.Nr.
Stand-alone transverse table ...................................................................................................... Art.Nr.
Transverse table with telescopic arm .......................................................................................... Art.Nr.
Articulated arm ............................................................................................................................ Art.Nr.
Additional set-down table ............................................................................................................ Art.Nr.
Stop rail ....................................................................................................................................... Art.Nr.
Workpiece clamp......................................................................................................................... Art.Nr.
You can nd further information at: www. scheppach.com or from your scheppach dealer
Electrical connection m
The electrical motor installed is connected and ready for opera-
tion. The connection complies with the applicable VDE and DIN
provisions.
The customer‘s mains connection as well as the extension
cable used must also comply with these regulations.
Motor braking device
Your scheppach machine is equipped with an automatic safety
brake. This brake engages when the drive motor is switched off.
The saw blade must have come to a standstill max. 10 seconds
after being switched off. Check daily!
Do not operate the machine if the brake time is longer.
Important information
The 230V / 50Hz and 400V / 50Hz electrical motors are desig-
ned for S6 / 40% operating mode.
In the event of an overloading the motor will switch itself off.
After a cool-down period (time varies) the motor can be swit-
ched back on again
Damaged electrical connection cables
The insulation on electrical connection cables is often damaged.
Causes are:
Pressure points, where connection cables are passed through
windows or doors.
Kinks where the connection cables have been improperly
fastened or routed.
Places where the connection cables have been cut due to
being driven over.
Insulation damage due to being ripped out of the wall outlet.
Cracks due to the insulation ageing.
Such damaged electrical connection cables must not be used
and are
mlife threatening due to the insulation damage.
Check the electrical connection cables for damage regularly. En-
sure that the connection cables are disconnected from electrical
power when checking for damage.
Electrical connection cables must comply with the applicable VDE
and DIN provisions. Only use connection cables with the marking
H 07 RN.
The printing of the type designation on the cable is mandatory.
AC motor
The mains voltage must be 230 Volts, 50 Hz..
Extension cables up to 25 m long must have a cross section
of 1.5 mm², and over 25 m long must have a cross section of
2.5 mm².
The mains connection must be protected with a 16 A slow-
blow fuse on the mains side
3-phase motor
The 400 V / 50 Hz electrical motor is designed for S6 / 40%
operating mode
The mains voltage must be 400 Volts, 50 Hz..
Mains connection and extension cables must be 5-core = 3 P
+ N + PE.
Extension cables must have a minimum cross section of 1.5
mm².
The mains connection must be protected with a 16 A fuse on
the mains side.
When connecting to the mains or in the event of the machine
being moved to another location, check the turning direction
of the saw blade. If necessary the polarity must be changed
(phase inverter, see start-up).
Connections and repair work on the electrical equipment may
only be carried out by electricians.
Please provide the following information in the event of any enqui-
ries.
• Article number of the motor
• Type of current for the motor
• Machine data - type plate
When returning the motor always send in the complete drive unit
with switches.
Maintenance and repair
All maintenance operations have to be carried out by qualied personnel in exact compliance with the existing manual.
Before each maintenance operation, all possible precautions have to be taken, the motor has to be turned off and the power supply
has to be disconnected (mains plug pulled out).
All safeguards have to be tted immediately after repair and maintenance have been completed.
Maintenance
Clear the machine and its surroundings of sawdust after each operation.
Occasionally, using dry lubricant, clean and treat the threaded spindle for
the cutting height adjustment as well as the gear rod with gear segment
36
DGB
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scheppach Forsa 3.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scheppach Forsa 3.0 in the language / languages: English, German as an attachment in your email.

The manual is 5.68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info